Setup Mode
47
3.11 B12-Label Specifications
Create and configure a Label Specification for any special label
parameters such as print direction, print speed, etc. The Label
Specification is linked to a Cassette in step B11-05. The service
password is required to access this feature.
B11-18—B11-20 Extra
Message 1-3
Select if the extra message height can change when B11-09 is set as
continuous.
0: Fixed height
1: Reduce the height as needed.
0: FIXED
1: VARIABL
B11-21 SH. Image
Select if the safe handling image space can contract if the image does not print
when B11-09 is set as continuous.
0: Fixed height
1: Reduce the height as needed.
0: FIXED
1: VARIABL
B11-22—B11-24 Image 1-3
Select if the logo image can contract if the image does not print when B11-09 is
set as continuous.
0: Fixed height
1: Expand the height as needed.
0: FIXED
1: VARIABL
B11-25 Height SH. Image
Set the value so a continuous label will compress when the safe handling image
is not printed. The value is calculated based on the height of the SH image.
0000
B11-26—B11-28 Height
Image 1-3
Set the value so a continuous label will compress when the logo image is not
printed. The value is calculated based on the height of the logo image.
0000
B11-29 Reserve
Not used.
0000
Display
Description
Choices
B12-01 Label Number
Label specification number.
01
-99
B12-02 Label Type
Select the Label Paper type.
130LA is the USA standard, there should be no reason to change
the default.
0: RECEIPT
1: 130LA-1
3: 150LA-1
B12-03 Back Feed
Select if backfeed is enabled. This allows variable data (other than the store name)
to print at the bottom of the label.
0: NO
1: YES
B12-04 Sensor Type
Select label sensor control.
0: NO USE
1: LABEL
B12-05 Print Direction
Set print direction.
0: Label prints in normal direction, bottom first
1: Label prints upside down, top first
0: STANDARD
1: REVERSE
B12-06 Feed Length
Set the feed length. The decimal point is not required.
0.0-999.9 (
7.5
)
B12-08 Format Number
Select a label format for test printing.
001
-999
B12-09 PLU Number
Select a PLU number for test printing.
0
-99999999
B12-10 Label Width
View the width of the label set in step B12-08.
--
B12-11 Label Length
View the length of the label set in step B12-08.
--
B-12-12 Label Gap
Enter the length of the gap between the labels in millimeters. The decimal point is
not required.
0.0-99.9 (
2.5
)
B-12-13 Sensor Distance Set the sensor distance in millimeters to adjust the label stop position at the
peel bar. This will also adjust the printing on the label. The decimal point is not
required.
0.0-999.9 (
71.0
)
B12-14 Print Density
Set the darkness of the thermal print from 0 (lightest) to 9 (darkest).
0-9 (
5
)
Table 3-11. B12 Label Specifications Parameters
Display
Description
Choices
Table 3-10. B11 Cassette Parameters (Continued)
B12 LABEL SPEC.
EODEHOVSHF
Note