Chapter 6 SETUP MODE
6-92 UNI-3 Service Manual
Dot display
Segment display
Setting value
*ZERO PRIC 1
B18-01-01 0 ZERO PRIC 1
Select processing when amount is 0
yen
1:
BAR 0/No amount
2:
NO. BAR/Amount 0
3:
NO PRICE/No amount
*ERROR TARE -1:NO B18-01-02 ERROR TARE
1
Tare error display
1:NO 2:YES
*ERROR ZERO PRICE –2:YES B18-01-03 ERR 0 PRICE 2
Amount 0 yen error detect
1:NO 2:YES
*NO POS ERR -1:NO DISP
B18-02-01 NO POS ERR 1
POS code set Error
1:NO DISP,2:NO PRNT,3:NO BAR
1: No error display
2: No label print
3: No barcode print
*DMG THER ERR -2:CONTI
B18-03-01 THERMAL ERR 2 Thermal head empty error detect
1:ONE TIME,2:CONTI,3:NO MESG
1: Detect first time
2: Detect each time
3: No error message
Setting for customization of UNI-3 error detection method
Items for which error detection is not required can be made to continuously operate by selecting No Error
Detection.
Summary of Contents for Uni-3
Page 10: ...TABLE OF CONTENTS viii UNI 3 Service Manual MEMO ...
Page 18: ...Chapter 1 BASIC INFORMATION 1 8 UNI 3 Service Manual MEMO ...
Page 19: ...Chapter 2 ASSEMBLY DRAWINGS UNI 3 Service Manual 2 1 ASSEMBLY DRAWINGS 2 1 BENCH TYPE L2 2 ...
Page 21: ...Chapter 2 ASSEMBLY DRAWINGS UNI 3 Service Manual 2 3 2 2 BENCH TYPE L1 ...
Page 23: ...Chapter 2 ASSEMBLY DRAWINGS UNI 3 Service Manual 2 5 2 3 POLE TYPE L2 ...
Page 25: ...Chapter 2 ASSEMBLY DRAWINGS UNI 3 Service Manual 2 7 2 4 POLE TYPE L1 ...
Page 30: ...Chapter 3 BLOCK DIAGRAMS 3 4 UNI 3 Service Manual MEMO ...
Page 38: ...Chapter 4 ELECTRICAL SIGNALS 4 8 UNI 3 Service Manual MEMO ...
Page 50: ...Chapter 5 MACHINE DISASSEMBLY 5 12 UNI 3 Service Manual ...