Chapter 7 ADJUSTMENT MODE
7-48
UNI-3 Service Manual
8.CALIBRATION
The dot display
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
C 0 8 C A L I B R A T I O N
The segment display
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20 21 22 23
C 0 8 C A L I B R A T I O N
1
:
CAPACITY 0:15kg 1:30kg
2
:
RANGE 0:SINGLE 1:MULTI
3
:
AREA SETTING
4
:
Adv. SETTING
9
:
INITIALIZE
10
:
SPAN
11 : A/O CONV. RATE
12 : STABLE COUNT
13 : RE-STABLE COUNT
14 : WGT POLL
Function key:
[
INITIAL
]:
Initialization (A/D parameter)
[
ZERO
]:
Compensation of zero point
[
SPAN
]:
Weight calibration
[+]:
Span fine adjustment Plus compensation
[-]:
Span fine adjustment Minus compensation
While retrieving an AD transformation parameter, the buzzer sounds at every access to A/D board. The zero point
is reset after completing the calibration (calibration mode).
Summary of Contents for Uni-3
Page 10: ...TABLE OF CONTENTS viii UNI 3 Service Manual MEMO ...
Page 18: ...Chapter 1 BASIC INFORMATION 1 8 UNI 3 Service Manual MEMO ...
Page 19: ...Chapter 2 ASSEMBLY DRAWINGS UNI 3 Service Manual 2 1 ASSEMBLY DRAWINGS 2 1 BENCH TYPE L2 2 ...
Page 21: ...Chapter 2 ASSEMBLY DRAWINGS UNI 3 Service Manual 2 3 2 2 BENCH TYPE L1 ...
Page 23: ...Chapter 2 ASSEMBLY DRAWINGS UNI 3 Service Manual 2 5 2 3 POLE TYPE L2 ...
Page 25: ...Chapter 2 ASSEMBLY DRAWINGS UNI 3 Service Manual 2 7 2 4 POLE TYPE L1 ...
Page 30: ...Chapter 3 BLOCK DIAGRAMS 3 4 UNI 3 Service Manual MEMO ...
Page 38: ...Chapter 4 ELECTRICAL SIGNALS 4 8 UNI 3 Service Manual MEMO ...
Page 50: ...Chapter 5 MACHINE DISASSEMBLY 5 12 UNI 3 Service Manual ...