Chapter 7 ADJUSTMENT MODE
7-54
UNI-3 Service Manual
C08-10 SPAN CALIBRATION
The dot display
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
* C A L I B . S P A N W E I G H T
The segment display
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20 21 22 23
C 0 8 - 1 0 # # # # # * * * * *
###: Monitoring of A/D value
***: Monitoring of measuring value
Span adjustment (Calibration)
[
ZERO
]:
Adjustment of zero point (Adjust the real zero to 20000 count)
[
TARE
]:
Adjustment of span
(
60000 count
/
75000 count
)
[
’
]:
Span fine adjustment Plus compensation
[
•
]:
Span fine adjustment Minus compensation
30lb
:
1/60000
15kg
:
1/75000