background image

 

 

 

 

 

1

 

Features 

 

Congratulations on your purchase of a DuraPanel. This short form manual is designed to get 

you started working with your new DuraPanel.  

 

The DuraPanel series of Panel Computers are all designed for the demanding operating 

conditions at sea. 

 

The DuraPanel series are tested for full compliance to marine-standards IACS E10 and IEC 

60945. 

 

The DuraPanel comes with excellent brightness and contrast levels that, together with wide 

viewing angles, ensure a good readability thus making it very eye-friendly. For the best picture 

quality, always use a double shielded DVI or VGA cable with ferrites on external monitor.  

 

 

 

2

 

General considerations on Installation and 

Operation 

 

The DuraPanel is designed to work at conditions according to IEC 60945. However, keeping the 

temperature and vibration level at a minimum will extend the life time of the product. ISIC 

recommend operating this product at normal room temperature (20-25 °C), with the lowest 

level of vibration and humidity.  

 

Installation of the DuraPanel 

 

In order to obtain the best possible operating conditions, please note the following precautions. 

 

-

 

Room for cooling. 

When designing the cabinet/console for the DuraPanel, please ensure that air can 

flow freely around the cabinet, in order to avoid any unnecessary rise in 

temperature. If it is not possible to have an adequate natural airflow, use a fan to 

force the airflow to be higher. 

 

-

 

Mounting positions 

The DuraPanel is designed for both horizontal and vertical installation. 

 

-

 

Sunlight 

Avoid direct sunlight to keep temperature low by that improve lifetime.  

 

User Reference Manual – DuraPanel series 

PN: 07353-000 Rev B Page 4 

Summary of Contents for DuraPanel 7"

Page 1: ...User Manual DuraPanel Series DuraPanel 7 DuraPanel 12...

Page 2: ...installed and used in accordance with the instructions advised by ISIC A S it may cause interference to radio communication The DuraPanel series manufactured by ISIC A S is designed to comply with th...

Page 3: ...IMULATION 13 11 MECHANICAL OUTLINE DURAPANEL 7 OPTIONAL FAN 14 12 MECHANICAL OUTLINE DURAPANEL 12 INCH FLUSH 15 13 MECHANICAL OUTLINE DURAPANEL 12 INCH RETROFIT 16 14 MECHANICAL OUTLINE DURAPANEL 12 I...

Page 4: ...conditions according to IEC 60945 However keeping the temperature and vibration level at a minimum will extend the life time of the product ISIC recommend operating this product at normal room temper...

Page 5: ...nel 3 1 DuraPANEL7 connections Optional fan output 3 2 DuraPANEL12 connections FAN PWR 4 x USB 4 x LAN Serial DVI I 2 x PWR DC RESET CHASSIS FAN PWR 2 x USB 4 x LAN Serial 2 x PWR DC RESET DVI I CHASS...

Page 6: ...3 TxD Rx 4 DTR Rx 5 GND 6 DSR 7 RTS 8 CTS 9 RI COM2 settings RS232 422 485 is set in BIOS 4 1 DuraPANEL12 Serial COM port used for external communication COM1 COM port used for internal communication...

Page 7: ...two independent galvanic isolated power inputs Mating part number Weidm ller BLZP5 08HC 02 180F Pin Power in 1 0VDC 2 24VDC 4 3 Fan output Mating part JST XHP 2 housing SXH 001T P0 6 terminal Pin FAN...

Page 8: ...x 91 mm View angle 89 T B 89 L R typical Luminance 450 Cd m2 typical Optional Ambient light sensor Contrast ratio Touch 800 1 typical 10 finger PCAP touch internal USB interface Front glass Anti Refl...

Page 9: ...Front Display size 12 1 inch 16 10 LCD TFT MVA technology Resolution 1280 x 800 Active area 261 x 163 mm View angle 88 T B 88 L R typical Luminance 400 Cd m 2 typical Optional Ambient light sensor Con...

Page 10: ...outline DuraPanel 7 Drop in NJS 25 08 2015 General tolerances 0 2 Hole position 0 1 Angle straightness and flatness DS ISO 2768 H Scale Drawing no Replaces 07376 001 A Rev Subject ISIC A S Edwin Rahr...

Page 11: ...f 45 70207077 Web www isic dk This docoment contains proprietary information and is not to be used or reproduced without the written permission of ISIC A S ECO Material Surface Sheet 1 of 1 A1 1 1 VES...

Page 12: ...2 Hole position 0 1 Angle straightness and flatness DS ISO 2768 H Scale Drawing no Replaces 07376 002 A Rev Subject ISIC A S Edwin Rahrs Vej 54 DK 8220 Brabrand Tlf 45 70207077 Web www isic dk This do...

Page 13: ...rs Vej 54 DK 8220 Brabrand Tlf 45 70207077 Web www isic dk This docoment contains proprietary information and is not to be used or reproduced without the written permission of ISIC A S ECO Material Su...

Page 14: ...2768 H Scale Drawing no Replaces 07386 000 A Rev Subject ISIC A S Edwin Rahrs Vej 54 DK 8220 Brabrand Tlf 45 70207077 Web www isic dk This docoment contains proprietary information and is not to be u...

Page 15: ...v Subject ISIC A S Edwin Rahrs Vej 54 DK 8220 Brabrand Tlf 45 70207077 Web www isic dk This docoment contains proprietary information and is not to be used or reproduced without the written permission...

Page 16: ...erances 0 2 Hole position 0 1 Angle straightness and flatness DS ISO 2768 H Scale Drawing no Replaces 07377 001 A Rev Subject ISIC A S Edwin Rahrs Vej 54 DK 8220 Brabrand Tlf 45 70207077 Web www isic...

Page 17: ...e straightness and flatness DS ISO 2768 H Scale Drawing no Replaces 07377 004 A Rev Subject ISIC A S Edwin Rahrs Vej 54 DK 8220 Brabrand Tlf 45 70207077 Web www isic dk This docoment contains propriet...

Page 18: ...received successfully or a negative acknowledge NACK if the command contained errors Note that the interface board will acknowledge messages even if it fails to execute the actions contained within N...

Page 19: ...message with zero data This requirement does not apply to broadcasted messages 15 2 3 Data Sent DS The DS field is only transmitted as a mirror of the sent data 15 2 4 Data Field DATA The data field i...

Page 20: ...ATA field will be set to an ASCII string with the ISIC P N and revision Maximum length is 20 characters Example Ask for the Monitor Firmware Version ATTN ADDR CMD LEN IHCHK 0x07 0x00 0x56 0x45 0x52 0x...

Page 21: ...ge with the current fan state in the DATA field If the checksum was invalid the monitor will reply with a NACK message Example Turn the fan on ATTN ADDR CMD LEN IHCHK DATA IDCHK 0x07 0x00 0x46 0x41 0x...

Page 22: ...x49 0x53 0x00 0x10 Reply from interface board 00100 ATTN ADDR CMD LEN IHCHK DATA IDCHK 0x06 0x00 0x4C 0x49 0x53 0x05 0x0C 0x30 0x30 0x31 0x30 0x30 0x0E 16 Backlight color etc settings The monitor of D...

Page 23: ...15W DuraPanel 12 20W 25W 19 In rush current Test object condition A 24VDC DuraPanel 7 85 DuraPanel 12 85 20 Troubleshooting Problem Cause Solutions No picture on display No power connected Apply power...

Page 24: ...enmark Bank Code 0892 SWIFT HANDDKKK IBAN for DKK DK53 0892 0001 0159 69 IBAN for EUR DK48 0892 0003 0026 19 IBAN for USD DK26 0892 0003 0026 27 Contacts RFQ s By fax to 45 70 20 79 76 By mail to sale...

Page 25: ...h the panel PC s Chapter 3 new DuraPANEL7 drawing in updated and RS232 changed to serial Chapter 4 RS422 485 information added in serial table updated with correct pin out DuraPANEL12 swapped COM1 COM...

Page 26: ...s of the warranty Monitor classification ISO 9241 307 2008 Allowed defects per type per million pixels Defect classes Pixel defects Cluster defect Type 1 Type 2 Type 3 total 2xN3a N3b Type 1 Type 2 Ty...

Page 27: ...tly dark Cluster A cluster consists of 5 x 5 pixels Cluster pixel defect type 1 Cluster pixel defect type 2 Pixels in a cluster area constantly lit Pixels in a cluster area constantly dark Cluster pix...

Page 28: ...ications Screen type Native resolution Number of pixels Pixel defect type 1 Pixel defect type 2 Pixel defect Type 3 total 2xN3a N3b Cluster defect type 1 and 2 Cluster defect type 3 WVGA 800x480 384 0...

Page 29: ...25 Appendix B Certificate of Conformity User Reference Manual DuraPanel series PN 07353 000 Rev B Page 29...

Page 30: ...Edwin Rahrs Vej 54 DK 8220 Brabrand Denmark Web http www isic systems com Email service isic systems com User Reference Manual DuraPanel series PN 07353 000 Rev B Page 30...