Replacing the SAS drive controller card
The serial-attached SCSI (SAS) drive controller card attaches to the riser card assembly and coordinates communication
between the node hard drives. Replace a failed SAS card as soon as possible to reduce node downtime.
Prerequisite: Before replacing the SAS drive controller card, you must remove the PCI Express riser card assembly.
For more information, see
Removing the riser card assembly
on page 25.
1. Verify that the drive cables are labeled with their corresponding port ID numbers. If they are not, label them before
disconnecting them from the SAS drive controller card.
2. Disconnect the drive cables from the SAS drive controller card.
3. Remove the SAS drive controller card from the riser card assembly.
2
3
4
1
5
4 Hard drive cable connection port
1 SAS drive controller card mounting screws
5 SAS drive controller card
2 Rear I/O panel
3 Riser card
Figure 19. Removing the SAS drive controller card
4. Install the new SAS controller card in the middle slot on the riser card.
5. Reconnect the drive cables to the corresponding ports on the SAS controller card.
6. Install the riser card assembly.
For more information, see
Installing the riser card assembly
on page 26.
7. Return the old hardware to Isilon Technical Support.
For more information, see
on page 6.
©