background image

®

Operating & Installation Instructions

AUSTRALIA

III BLU

Summary of Contents for III BLU

Page 1: ... Operating Installation Instructions AUSTRALIA III BLU ...

Page 2: ......

Page 3: ...OVE 10 HEALTH AND SAFETY PRECAUTIONS 10 FLUE 10 HEARTH AND FIRE SURROUND 10 CONNECTIONS TO FLUES 11 PRE LIGHTING CHECK 11 COMMISSIONING 11 INSTALLATION INSTRUCTIONS 11 CLEARANCES 12 STANDARD HEARTH DIMENSIONS 13 CORNER HEARTH DIMENSIONS 14 FLUE CLEARANCES DIAGRAM 15 STANDARD DEFAULT TRIPLE SKIN FLUE KIT 16 INSULATED ROOM SEAL FLUE KIT 17 INSULATED ROOM SEAL FLUE KIT 18 INSULATED ROOM SEAL FLUE KIT...

Page 4: ...LING THE FIRE Add kindling and paper or firelighters Keep air control fully out and door cracked open Once kindling is alight add smaller logs Keep air control fully out and close door Add larger logs once fire is established Air control can be reduced to minimum MAINTENANCE AND CLEANING GLASS Wipe with damp lint free cloth Any stubborn deposits on the glass may be removed with a proprietary stove...

Page 5: ...t and split and then left to season in a well ventilated dry place for at least one year but preferably two years before use Approximate suitable log sizes are Island III blu 550mm 21 6in long and 100mm 4in diameter Log moisture content of less than 20 is recommended PETROLEUM COKE IS NOT SUITABLE FOR USE ON THIS APPLIANCE ITS USE WILL INVALIDATE THE GUARANTEE This stove is not designed to burn ho...

Page 6: ... the grate from one position to the other is effected using the tool supplied as shown in Fig 2 The grate is put into the open position by moving the tool up until the handle is in the 1 o clock position The grate is put into the closed position by moving the tool down until the handle is in the 5 o clock position To riddle the appliance the tool should be moved between the open and horizontal pos...

Page 7: ...ing most suitable for the type of fuel being used and the draw on the flue MAINTENANCE Cleaning The stove is finished with a high temperature paint which will withstand the temperatures encountered in normal use This may be cleaned with a damp lint free cloth when the stove is cold Should re painting become necessary high temperature paints are available from your supplier or from stove shops Clea...

Page 8: ...alternative means such as a flue access door After clearing any soot from within the stove replace the baffle see Fig 8 It is important to use the correct flue brush for the flue size different types of sweep s brushes are available to suit different flue For prefabricated insulated flues the manufacturers instructions with regard to sweeping should be consulted TROUBLE SHOOTING Fire Will Not Burn...

Page 9: ... been identified if necessary seek professional advice The most common cause of fume emission is a flue blockage For your own safety the flue must be kept clean Fire blazing out of control Check that a The door is tightly closed b The air control slider is fully closed c A suitable fuel is being used d Door seals and air slide are intact Flue Fires If the flue is thoroughly and regularly swept flu...

Page 10: ...hen warm minimum of 12pa 0 05 wg The height of the flue must comply with local building regulation requirements The internal dimensions of the flue MUST NOT BE LESS THAN 175mm 7 The listed flue s construction and installation must comply with the requirements of AS NZS2918 2018 and must also meet local building codes The flue must be suitable for burning solid fuel lined in good condition and at l...

Page 11: ...that the baffle and upper baffle is fitted in the roof of the appliance For location and positioning see Fig 5 Check that the front fence is fitted correctly and that the door closes properly COMMISSIONING Ensure that the rear heatshield extension is fitted to the back of the heaishield part 010 CZEA170 with 2 x 12mm self tapping screws This part must be supplied and fitted to the stove On complet...

Page 12: ...12 CLEARANCES A A B A B C D PARALLEL POSITION COMBUSTIBLE WALLS CORNER POSITION Standard Clearance A 300mm B 471mm C 525mm D 907mm ISLAND III BLU Corner Clearance A 350mm B 706mm ...

Page 13: ...55mm C 300mm D 350mm E 300mm TO WALL MIN DIMENSIONS TO WALL A 1463mm B 955mm C 300mm D 350mm E 525mm VERTICAL REAR FLUE ADAPTOR VERTICAL REAR FLUE ADAPTOR ISLAND III BLU NON COMBUSTIBLE MATERIAL Minimum thickness 24mm Minimum thermal resistivity 0 104m2 K W Installed in accordance with AS NZS 2918 2018 3 3 2 B C D D A B E C D D A B E C D D A ...

Page 14: ...EAR FLUE ADAPTOR CORNER HEARTH A 955mm B 706mm C 300mm WITH VERTICAL REAR FLUE ADAPTOR A 955mm B 706mm C 525mm D 300mm ISLAND III BLU C A B B B B C D D A NON COMBUSTIBLE MATERIAL Minimum thickness 24mm Minimum thermal resistivity 0 104m2 K W Installed in accordance with AS NZS 2918 2018 3 3 2 ...

Page 15: ... top Increase from 1000 min until clear within 3000 of flue top DIMENSIONS IN MILLIMETRES Summary of minimum height of flue sytem exit requirements from AS NZS 2918 2018 More than 3000 More than 3000 600 min 600 min 3000 Any nearby structure Increase as necessary until nothing within 6000 of flue top ...

Page 16: ...16 150 1000 1000 1000 1000 25 600 Cowl Triple skin flue Flashing Optional Decorative Flue Solid OR Mesh Ceiling Ring Dropbox STANDARD DEFAULT TRIPLE SKIN FLUE KIT ...

Page 17: ...17 INSULATED ROOM SEAL FLUE KIT 185 1000 1000 1000 25 50 Single skin flue Room sealed flue adaptor Ceiling ring Heatshield Starter length flue Cowl Room sealed flue with locking band STANDARD FLUE KIT ...

Page 18: ...18 INSULATED ROOM SEAL FLUE KIT FULLY SEALED FLUE KIT 1000 1000 1000 1000 25 50 Cowl Ceiling ring Heatshield Starter length flue Room sealed flue with locking band ...

Page 19: ...mm clearance to any timber to the side and underneath Min 470 Max 620 Cowl Adjustable wall bracket Cleaning access Wall Plate INSULATED ROOM SEAL FLUE KIT REAR FLUE KIT Room sealed flue with locking band Room sealed flue with locking band Room sealed flue adaptor 90 degree tee with cap Wall plate gal Ceiling ring Roof support brace ...

Page 20: ...20 COMPLIANCE DATA ISLAND III BLU COMPLIANCE DATA Compliance plate riveted onto rear heatshield ...

Page 21: ...21 ISLAND III BLU DIMENSIONS ...

Page 22: ...6 R H Door Handle 24 002 AY14 Door Catch Cam 25 008 FFW015 M12 Double Coil Spring Washer 26 004 ST008 Tabbed Locking Washer 27 008 FFN001 M12 Half Nut 28 008 KV13 L H Door Knob 29 008 BW39 S Hinge Pin Set 30 002 PY24 Hinge Post 31 008 AY37 Air Control Knob 32 008 PX95 Riddling Ashpan Tool 33 004 BX048 Tool Holder 34 002 PX89 Riddler Knob 35 004 CY21 Air Bypass Slide 36 004 CY22P Primary Air Inlet ...

Page 23: ...and must be accompanied by proof of purchase Nothing in this guarantee shall affect your statutory rights EXCLUSIONS AND LIMITATIONS This Guarantee does not cover the following Charnwood will not be liable for any consequential loss or incidental loss damage or injury however caused This guarantee will become void if the appliance is not installed by a suitably qualified and is not installed in ac...

Page 24: ...your premier dealer ...

Reviews: