background image

Warning

  

. . . . . . . . . .

 . . . . . . . . . .
 . . . . . . . . . .
 . . . . . . . . 

Safety 

 . . . . . . . . .  
 . . . . . . . . . .
 . . . . . . . . . .
 . . . . . . . .

 . . . . . . . . .

 

 

Read First

 

Symbols as marked on the Tester 

and Instruction card

 

 

 

Risk of electric shock 

 

 

See instruction card 

 

 

DC measurement 

 

 

Equipment protected by double or 

reinforced insulation 

 

<

 

Battery 

 

 

Earth 

 

 

AC measurement 

 

 

Conforms to EU directives 

E

 

Application around and removal 

from hazardous live conductors is 

permitted  

 

Do not discard this product or  

throw away 

Power On / Off

 

 

The Meter displays Battery Capacity 

    when powering up. Please replace the 
    battery when 0% is shown. 

 

 Caution 

  

The Tester powers up in 

 

/ continuity  

mode.

 

Auto Power Off

 

Auto Power Off  Enable / 
Disable

 

Fail of usage

Ready to use

• 

Do not measure while powering up, it  

    will cause Self-Testing failure. 

 Caution 

  

Do not use the Meter when “FAIL” is 
shown. Undiscovered failure could exist  
even “FAIL” is not shown.

 

Auto Hold Enable / Disable 

 

Self-Testing Aid

 

Continuity

 

Instruction Manual 
ICM A9  
Electrical Clamp-Multimeter     

EN

 

 

ICMA9

 

Safety Information 

To ensure safe operation and service of 
this Clamp-multimeter, read these  
instructions completely before use and 
comply with them fully when using it.  
Failure to observe these warnings can 
result in severe 

injury

 or 

death. 

-

 Avoid working alone so assistance can  

  be rendered. 

Do not use test leads or the Tester if  

  they look damaged.  

Do not use the Tester if the Tester is  

  not operating properly or if it is wet. 

Use the Tester only as specified in the  

  Instruction card or the protection by  
  the Tester might be impaired. 

Use extreme caution when working  

  around bare conductors or bus bar.  
  Contact with the conductor could  
  result in electric shock. 

Do not use the Tester to measure volt- 

  ages in circuits that could be damaged 
  by the Tester’s low input impedance 
  (approximate 4K

Use caution with voltages above 30 V  

  ac rms, or 60 V dc. These voltages  
  pose a shock hazard. 

Summary of Contents for ICM A9

Page 1: ... Enable Disable Self Testing Aid Continuity Instruction Manual ICM A9 Electrical Clamp Multimeter EN ICMA9 Safety Information To ensure safe operation and service of this Clamp multimeter read these instructions completely before use and comply with them fully when using it Failure to observe these warnings can result in severe injury or death Avoid working alone so assistance can be rendered Do n...

Page 2: ...gnal different from the LCD reading 2 The measured signal is the same as the LCD reading and is larger 50 counts than the LCD reading Auto Hold ACA only I 100A 3 0A 2 Beep three times 1 2 0A 3 After 5Sec 1 4 CAT Ⅲ 600V with respect to earth for the jaw Barrier for Hand Guard Do not hold the meter across the Barrier Caution When connecting the test leads to the circuit or device connect the black l...

Page 3: ...f resistance 2 times sec of ACA Overrange display OL is displayed for Ω function shows the real value for A and V function Automatic power off time Approximately 20 minutes after power on without operations Low battery indicator is displayed Replace the battery when the indicator appears in the display Power requirement 9V battery Battery type and life ALKALINE PP3 9V 250 hours Ⅰ The circuits not ...

Page 4: ...ose are limited to the above The manufacturer shall not be liable for loss of use of the instrument or other incidental or conse quential damages expenses or economic loss or for any claim or claims for such damage expense or economic loss Some states or countries laws vary so the above limitations or exclusions may not apply to you For full terms and conditions refer to the current RS Catalogue A...

Reviews: