SECTION 1 –SAFETY INFORMATION

  

Safety Information

Understand and follow operating instructions carefully.

Use the instrument only as specified in this manual; otherwise, the 

protection provided by the instrument may be impaired.

  

WARNING

Identifies hazardous conditions and actions that could cause 

BODILY 

HARM

 or 

DEATH

  

CAUTION

Identifies conditions and actions that could DAMAGE the instrument or 

equipment under test

  

  

WARNING

 -  Examine the instrument and probes before use. Do not use the 

instrument if it is wet or damaged

 -  When using test leads or probes, keep your fingers behind the finger 

guards. 

 -  Remove the test lead from the instrument before opening the battery 

cover or instrument case. 

 -  Always use the correct terminals, switch position and range for 

measurements. 

 -  Never attempt a voltage measurement with the test leads inserted into 

the “A”input terminals. 

 -  Verify the instrument is operating correctly by measuring a known 

voltage before use. If in doubt, have the instrument serviced. 

 -  Do not apply more than the rated voltage, as marked on the 

instrument, between terminals or between any terminal and earth 

ground. 

 -  Do not attempt a current measurement when the open-circuit voltage 

is above the fuse protection rating. 

 -  Only replace a fuse with the correct type and rating as specified in this  

instruction manual. 

 -  Use caution when measuring voltages above 30 Vac rms, 42 Vac 

peak or 60 Vdc. These voltages pose a shock hazard. 

 -  To avoid false readings that can lead to electric shock, replace the 

battery as soon as the low battery indicator appears in the display. 

 -  Disconnect the circuit power and discharge all high-voltage capacitors 

before making resistance, current, continuity, diode or capacitance 

measurements. 

 -  Do not use the instrument in a hazardous area or around explosive  

gasses or vapours.

 -  Wear suitable personal protective equipment when working around or 

near hazardous live conductors which could be accessible.

Risk of electric shock

See instruction manual

DC measurement

Equipment protected by double or reinforced Insulation

Battery

Fuse

Earth

AC measurement

 

Conforms to EU directives

Dispose of in accordance with local regulations.

 CAUTION

•  Disconnect the test leads from the test points before changing the 

position of the function rotary switch.

•  Never connect a source of voltage with the function rotary switch in 

the  

“Ω”, “ ”, “°C” , “mA”, or “A” position.

•  Do not expose the instrument to extremes in temperature or high 

humidity.

•  Never set the instrument in the “Ω”, “ ”, “°C” , “mA”, or “A” position 

to measure  

the voltage of a circuit, this could result in damage the instrument and 

the  

equipment under test.

•  If possible, do not work alone, so assistance can be given if required 

The following symbols may appear on the instrument 

and this instruction manual:

Unsafe Voltage

To alert you to the presence of a potentially hazardous voltage, when the 

instrument detects a voltage 

30 V or a voltage overload (OL) in V, mV . 

The   symbol is displayed.

Maintenance

Do not attempt to repair this instrument. It contains no user-serviceable parts. 

Repair or servicing should only be performed by qualified personnel. This 

instrument should be calibrated yearly, or more frequently if used in harsh 

conditions or if it is suspected of being inaccurate. 

Summary of Contents for IDM 98-III

Page 1: ...963 Europe Iso Tech PO Box 99 Corby Northamptonshire NN17 9RS United Kingdom Japan Iso Tech West Tower 12th Floor Yokohama Business Park 134 Godocho Hodogaya Yokohama Kanagawa 240 0005 Japan USA Iso T...

Page 2: ...replace the battery as soon as the low battery indicator appears in the display Disconnect the circuit power and discharge all high voltage capacitors before making resistance current continuity diod...

Page 3: ...d Peak Hold 1ms IDM99 III only Min Max function AC DC function Frequency counter on AC mode Capacitance measurement Temperature measurement IDM99 III only Low battery indicator with segments Auto Powe...

Page 4: ...DC Current Rotate the switch and press the Function button to select the measuring function See Using the Function Buttons Measuring Frequency Rotate the switch and press the Function button to selec...

Page 5: ...de Rotate the switch and press the Function button to select the measuring function See Using the Function Buttons Measuring Temperature C F for IDM99 III only Rotate the switch and press the Function...

Page 6: ...he min and max input values When the input goes below the recorded min value or above the recorded max value the meter records the new value Press HOLD button to pause the recording Peak HOLD for IDM9...

Page 7: ...ver 50 counts when measuring AC or DC Voltage Current with Auto V LoZ Range VoltSense Press and hold down the VoltSense button down to activate the VoltSense function CAUTION The number of dashes disp...

Page 8: ...ant of 2 2ms 11A 1000V IR 20KA Fast acting fuse size 38 x 10mm DMM B 11A 20 000A 1000 VAC power factor 0 2 20 000A 1000 VDC time constant 10ms size 38 x 10mm CAUTION The following safety information m...

Page 9: ...titude 6561 7 ft 2000m Safety Complies with EN61010 1 UL61010 1 IEC 61010 1 CAT IV 600V CAT III 1000V Measurement Category Application I Measurements on circuits not directly connected to mains Exampl...

Page 10: ...0 01V 1 0 3d 0 80 5d 600 0VAC 0 1V 1 0 3d 0 80 5d 1000VAC 1V 1 0 3d 0 80 5d 2 Auto V Input Protection 1000VDC or 1000VAC rms AC Frequency Response 50Hz 1KHz Input Impedance Approx 3k AC Conversion Ty...

Page 11: ...01K 600 0K 0 1K 6 000M 0 001M 40 00M 0 01M 1 0 5d IDM98 III IDM99 III Range Resolution Accuracy 600 0 0 1 0 8 5d 7 Diode Test Input Protection 1000VDC or 1000VAC rms Max Open Circuit Voltage Approxima...

Page 12: ...AC DC mV Additional specification are same as voltage function IDM99 III Range Resolution Accuracy 40 0 C 400 C 0 1 C 1 0 10d 40 0 F 752 F 0 1 F 1 0 18d IDM98 III IDM99 III Range Resolution IDM98 III...