IDM 98III / 99III English

IDM 98III / 99III English

16

17

Low battery and Battery Replacement

Replace the battery as soon as the low battery indicator appears to avoid 

false reading.

Refer to the following figure to replace the batteries

SECTION 5 - SPECIFICATIONS

General Specifications

Maximum voltage applied to any terminal

 : 1000 Vac rms or 1000 Vdc. 

rms

Display

 : 6000 counts. 

Polarity Indication

 : Automatic, positive implied, negative indicated.

Overrange Indication

 : OL

Batteries Life

 : 150hours alkaline battery (No backlight)

Low Batteries Indication

 : Voltage drops below operating voltage, “ ” 

will flash.

Power Requirement 

: PP3 9V battery

Auto Power Off 

: 20 minutes.

Operating Temperature

 :  -10 ~10°C

 

10°C ~ 30°C (

80% RH), 

 

30°C ~ 40°C (

75% RH),

 

40°C ~ 50°C (

45%RH)

Storage Temperature

 : -20°C  to 60°C , 0 to 80% R.H. (batteries not 

fitted)

Temperature Coefficient

 : 0.15 x (Spec.Accy) / °C, < 18°C  or > 28°C .

Measure

 : Samples 3 times per second .

Altitude

 : 6561.7 ft (2000m)

Safety

 : Complies with EN61010-1, UL61010-1,IEC 61010-1, CAT IV 

600V, CAT III 1000V

Measurement 

Category

Application

I

Measurements on circuits not directly connected  

to mains. Examples include: Measurements on battery 

powered equipment and specially protected (internal) 

mains-derived circuits.

II

Measurements on circuits directly connected to the 

low voltage installation. Examples include: Household 

appliances, portable tools and similar equipment.

III

Measurements performed in the building installation. 

Examples include measurements on distribution 

boards, junction boxes, socket-outlets and wiring and 

cables in the fixed installation.

IV

Measurements performed at the source of the low-

voltage installation. Examples include measurements 

on primary overcurrent protection devices and 

electricity Instruments

Weight

 : 460g (including battery)

Dimensions (W x H x D)

 : 94mm x190mm x 48mm with holster.

Pollution degree

 : 2 

EMC

 : EN 61326-1  

Shock vibration

 : Sinusoidal vibration per MIL-PRF- 28800F   

(5 ~ 55 Hz, 3g max.)

Drop Protection

 : 4 feet drop to hardwood on concrete floor.

Indoor use only.

Summary of Contents for IDM 98-III

Page 1: ...963 Europe Iso Tech PO Box 99 Corby Northamptonshire NN17 9RS United Kingdom Japan Iso Tech West Tower 12th Floor Yokohama Business Park 134 Godocho Hodogaya Yokohama Kanagawa 240 0005 Japan USA Iso T...

Page 2: ...replace the battery as soon as the low battery indicator appears in the display Disconnect the circuit power and discharge all high voltage capacitors before making resistance current continuity diod...

Page 3: ...d Peak Hold 1ms IDM99 III only Min Max function AC DC function Frequency counter on AC mode Capacitance measurement Temperature measurement IDM99 III only Low battery indicator with segments Auto Powe...

Page 4: ...DC Current Rotate the switch and press the Function button to select the measuring function See Using the Function Buttons Measuring Frequency Rotate the switch and press the Function button to selec...

Page 5: ...de Rotate the switch and press the Function button to select the measuring function See Using the Function Buttons Measuring Temperature C F for IDM99 III only Rotate the switch and press the Function...

Page 6: ...he min and max input values When the input goes below the recorded min value or above the recorded max value the meter records the new value Press HOLD button to pause the recording Peak HOLD for IDM9...

Page 7: ...ver 50 counts when measuring AC or DC Voltage Current with Auto V LoZ Range VoltSense Press and hold down the VoltSense button down to activate the VoltSense function CAUTION The number of dashes disp...

Page 8: ...ant of 2 2ms 11A 1000V IR 20KA Fast acting fuse size 38 x 10mm DMM B 11A 20 000A 1000 VAC power factor 0 2 20 000A 1000 VDC time constant 10ms size 38 x 10mm CAUTION The following safety information m...

Page 9: ...titude 6561 7 ft 2000m Safety Complies with EN61010 1 UL61010 1 IEC 61010 1 CAT IV 600V CAT III 1000V Measurement Category Application I Measurements on circuits not directly connected to mains Exampl...

Page 10: ...0 01V 1 0 3d 0 80 5d 600 0VAC 0 1V 1 0 3d 0 80 5d 1000VAC 1V 1 0 3d 0 80 5d 2 Auto V Input Protection 1000VDC or 1000VAC rms AC Frequency Response 50Hz 1KHz Input Impedance Approx 3k AC Conversion Ty...

Page 11: ...01K 600 0K 0 1K 6 000M 0 001M 40 00M 0 01M 1 0 5d IDM98 III IDM99 III Range Resolution Accuracy 600 0 0 1 0 8 5d 7 Diode Test Input Protection 1000VDC or 1000VAC rms Max Open Circuit Voltage Approxima...

Page 12: ...AC DC mV Additional specification are same as voltage function IDM99 III Range Resolution Accuracy 40 0 C 400 C 0 1 C 1 0 10d 40 0 F 752 F 0 1 F 1 0 18d IDM98 III IDM99 III Range Resolution IDM98 III...

Reviews: