background image

iSocket

®

 GSM 706/707 

                                                                          

               www.isocket.eu

 

© Copyright Intellectronics 2012 
All rights reserved. Version 1.1.2-EN 

             - 17 - 

         English

 

 
If  you  need  to  know  when  the  temperature  drops  below  the  specified  level,  set 
TFALLALERT.  If  you  need  to  know  when  the  temperature  exceeds  the  specified  value, 
set TRISEALERT. This feature might not be available on the "ISGSM706xx" models. This 

feature  is  available  on  the  "ISGSM707xx"  models.  However  this  feature  is  considered 
experimental. 

Correct  operation  of  these  experimental  features  cannot  be 

guaranteed. We reserve the right to remove these features in future versions 
of devices. The absence or incorrect function of these features on your device 
will not be covered by warranty.

 

 
Please note, information about the temperature can be available 10 minutes after the 
device is switched on. 

7.4 Temperature Calibration 

Temperature  measurements  are  often  influenced  by  internal  heating  from  the  built-in 
electronics, so the built-in thermometer can give temperature readings which are a little 
higher than the actual. For this reason a temperature calibration constant is factory-set, 

based on practical experience, to the value of 5 which means 5C or 41F. This calibration 
can be changed individually for each monitored environment. The value can be  decided 
empirically, by comparing with the exact thermostat temperatures measured. 

 

Command 

Description 

Response 

Type 

TEMPCAL=7 

Change calibration constant (from 1 to 9) 

The meanings of calibration constants: 

1 – 1C – 33.8F 

2 – 2C – 35.6F 

3 – 3C – 37.4F 

4 – 4C – 39.2F 

5 – 5C – 41.0F 

6 – 6C – 42.8F 

7 – 7C – 44.6F 

8 – 8C – 46.4F 

9 – 9C – 48.2F

 

TEMPCAL=7 – OK 

30min 

TEMPCAL? 

Show current calibration constant 

TEMPCAL=5 

Inf 

8. Date and Time

 

The features described in this chapter are not available on the "Light" models. 

 
Date and time are used for logging alarms (Chapter 9.3) and to configure the scheduler 
(Chapter 11). The date can also be seen in the 

STATUS

 response.  

 
The  device  automatically  sets  the  date  as  soon  as  you  start  to  use  it.  No  action  is 

required!  However,  if  for  some  reason  at  the  beginning  of  the  operation  an  incorrect 
date  or  time  was  set,  and  then  set  it  again  manually  or  automatically.  Automatic 
date/time settings are based on the GSM operator's network date/time.  
 

The device saves date and time settings for several hours after a power failure. 
 

Command 

Description 

Response 

Type 

DATESMS 

This message is automatically set with the date 

based on time taken from the SMS 

DATE yy/mm/dd, 

hh:mm:ss+zz – OK 

30min 

DATE=yy/mm/dd,hh
:mm:ss+zz 

Manually set the date and time 
zz – is GMT time zone 

DATE=yy/mm/dd, 
hh:mm:ss+zz – OK 

30min 

DATE 

Request for actual date and time in device 

DATE yy/mm/dd, 
hh:mm:ss+zz 

Ctrl 

Summary of Contents for GSM 706

Page 1: ......

Page 2: ...play commands associated with optional features The documentation and product are subject to change without notice The software supplied with this product is the exclusive property of Intellectronics...

Page 3: ...nd Commands From Unauthorised Users 14 7 Measurement and Control of Temperature 15 7 1 Thermometer 15 7 2 Thermostat 15 7 3 Temperature Monitoring Notifications iSocket Temperature Notifier 16 7 4 Tem...

Page 4: ...ecial connector Notification will be sent when it is triggered For example it could be a motion sensor an opening doors sensor fire detector gas leakage detector and many more A built in microphone al...

Page 5: ...et manual Chapter 4 3 or reset device Chapter 15 Built in microphone Chapter 10 not available in Light model Plug to connect iSocket GSM 706 707 to the wall socket to provide power for device and for...

Page 6: ...e shows model ISGSM706UK ISGSM707UK Socket Plug NEMA 5 15 Model Numbers ISGSM706US ISGSML706US ISGSM707US ISGSML707US The figure shows model ISGSM706US ISGSM707US Socket Plug CEE 7 5 French Model Numb...

Page 7: ...ical network meets safety standards The product is designed for indoor use in dry area Do not use it in wet or chemically aggressive environments For example do not use it in the bathroom It is also n...

Page 8: ...n a car that is parked in sunshine If the battery suffers overloading and or overheating the integrated protective cut off will switch off the charging discharging for safety reasons If this happens y...

Page 9: ...n was turned off If the SIM card is not inserted correctly or is damaged the indicator POWER and OUT will signal this by specific blinks see Chapter 16 All indicators blink three times simultaneously...

Page 10: ...ut only inform you of the value These commands are available at any time You can set up the facility to reset the configuration interval see section 5 3 Control and management commands marked Ctrl in...

Page 11: ...lay OFF Signal Good 67dBm TEMP 25C ALARMF Disabled ALARM status No activity Time y m d h m s Ctrl TEMPERATURE Informs about temperature in the room See details in Chapter 7 TEMPERATURE 25C Ctrl RUNTIM...

Page 12: ...device which is not advisable The device uses two methods of protection against unauthorised access Only allowing access to authorised phone numbers Authentication by password Both methods can be used...

Page 13: ...Chapter 6 3 lists more reasons for this alternative 5 2 Password Protection The following table shows how to set a password for managing access The password must consist of 5 characters Do not use a...

Page 14: ...successfully For this purpose we have implemented notifications of each executed command If you wish to receive execution confirmations the setting hide my number should not be activated on the phone...

Page 15: ...ecurity list was configured see Chapter 5 1 and someone tries to execute a command no response will be received until you install SMSCONFIRMUNAUTH ON If you set ON value for this parameter then unauth...

Page 16: ...utes after the power is switched on The temperature reading interval is 1 minute for models manufactured after July 2012 If the thermostat is enabled the first reading will occur 10 minutes after the...

Page 17: ...NUMBER 35 8912345678 Set the number for SMS This number is used in some other cases Chapters 9 2 11 and 12 You can install up to 10 numbers Instructions how to add a number are similar to those given...

Page 18: ...r each monitored environment The value can be decided empirically by comparing with the exact thermostat temperatures measured Command Description Response Type TEMPCAL 7 Change calibration constant f...

Page 19: ...rm function will send alerts and sound the siren if connected because the sensors have been activated In this event the alarm function can be deactivated manually by using the hidden button Push the h...

Page 20: ...device will not detect new sensor triggering The device will be ready to detect sensor activity no later than one minute after completion of the notification cycle If the sensor is still active at thi...

Page 21: ...designed for switching of external electrical contacts It can switch 24VDC 2A max Connectors and sensors are not supplied with the device These can be bought directly from us or our dealer network 10...

Page 22: ...at 18 00 SCHEDULER 17 00 6 INF Send status of iSocket every Saturday at 17 00 Status information is sent to the number specified by command ALERTNUMBER see Chapter 7 3 12 Status After Resumption of P...

Page 23: ...ALDOUMS NO Remove UMS code for balance from memory SALDOUMS NO OK 30min SALDOUMS Information about SALDOUMS settings SALDOUMS 100 Inf 14 Version Information Command Description Response Type HARDWARE...

Page 24: ...to GSM network MICROPHONE yellow No light Microphone is not active Lights constantly Microphone is active now Blinks every second Device is calling to somewhere for ex call alert OUT red No light Main...

Page 25: ...th Li ion battery Store conditions 30C 50C 22F 122F for the 706 models 0C 40C 32F 104F for the 707 models with Li ion battery Important notice The 706 models can operate at low temperatures in a dry p...

Page 26: ...at it was written correctly according to the manual Read about other potential problems below The OUT indicator reports an error blinking 4 times per second If the OUT indicator blinks 4 times per sec...

Page 27: ...y loss Intellectronics does not guarantee that this product will provide uninterrupted operation of the controlled equipment this device is not an uninterruptible power supply UPS This product is not...

Page 28: ...hout the express written consent of Intellectronics and any applicable third party You may not create derivative works or use any information available in this User Manual for commercial or public pur...

Reviews: