FIGURE 27
FIGURE 26
Required Clearances (when sheathing protrudes beyond front of firebox)
18
The Fire-Lite Series Isokern fireplace is tested and listed for 1 1/2” clearance to un-insulated wood framing material at the
firebox sides, back and at the smoke dome front, sides and back. However installation and use practices that are beyond the control
of the manufacturer* can create situations where a zero clearance installation can jeopardize the safety of combustibles in contact
with the Isokern surfaces resulting in fire damage to property, personal injury or loss of life.
*The manufacturer is not responsible for installation and use practices that are beyond the scope of the product as defined
in the product listing and in the installation manual.
WARNING: Do not pack or fill the air spaces with insulation or other material. No material is allowed in these areas.
The manufacturer strongly recommends that wherever possible, all combustible framing materials be kept a minimum of
1-1/2” clearance from the Isokern fireplace unit at the side walls and back walls. It is the responsibility of the General Contractor
to insure that listed clearances to combustible framing and to insulation are maintained throughout the construction of the project
subsequent to the installation of the Isokern unit.
FIGURE 28
Summary of Contents for FIRE-LITE series
Page 7: ...Assembled Firebox Smoke Dome Dimensions 36 42 46 7 ...
Page 23: ...23 Interior Masonry Veneer Fireplace Finishes Clearances FIGURE 38 FIGURE 36 FIGURE 37 ...
Page 28: ...DM 54 Chimney Component List Dimensions 28 ...
Page 32: ...32 DM 54 Chimney System Lateral Support cont FIGURE 51 FIGURE 52 ...
Page 51: ...51 Fire Lite Application Raised Metal Platform cont FIGURE 93 ...
Page 58: ...Notes 58 ...