1.
Before starting the assembly of the Fire-Lite read these
installation instructions carefully to be sure you understand
them completely. Failure to follow them could cause fireplace
malfunction resulting in serious injury or property
damage.
2.
Always check local building codes governing fireplaces
and fireplace installations. The Fire-Lite must comply with
all local, regional, state and national codes and regulations.
3.
The Fire-Lite must be installed with FTF-13 Class A Metal
Chimney System, or equivalent.
The Fire-Lite systems are intended for use in any application
where a traditional masonry type fireplace would apply.
The chimney system must always vent to the outside of the
building.
4.
Creosote and soot formation and the need for removal:
When wood is burned slowly it produces tar and other
organic vapors which combine with expelled moisture to
form creosote. The creosote vapors condense in the relatively
cool chimney flue of a slow burning fire. As a result,
creosote residue accumulates on the flue lining. When
ignited this creosote makes an extremely hot fire.
Because of creosote and soot buildup, it is necessary
to inspect and clean the fireplace and chimney prior to use
and periodically during the heating season. Cleaning of the
fireplace and the chimney system should be done annually at
a minimum. In colder climates chimney cleaning may need
to be done periodically throughout the heating season.
5.
Before servicing, allow the fireplace to cool. Always shut
off any electricity or gas to the fireplace while working on
it.
6.
Use only solid fuel or natural or LP gas log sets in this
unit. Do not use artificial wax based logs, chemical chimney
cleaners or flame colorants in this fireplace.
7.
Never use gasoline, kerosene, gasoline-type lantern fuel,
charcoal lighter fluid, or similar liquids to start or “freshen
up” a fire in this fireplace. Keep all flammable liquids at a
safe distance from the fireplace.
8.
Always keep the flue damper open when heat is present
in the fireplace.
9.
Do not use a fireplace insert or any other product not
specified for use with the Fire-Lite systems unless written
authorization is given by Isokern. Failure to heed this
warning may cause a fire hazard and will void the Isokern
warranty.
10.
This fireplace is not intended to heat an entire home or
to be used as a primary heat source. It is designed to ensure
homeowner comfort by providing supplemental heat to the
room.
11.
Always ensure that an adequate supply of replacement
combustion air from the outside of the house is accessible to
the fire to support normal combustion. Fireplaces consume
large volumes of air during the normal firing process.
In the event the home is tightly sealed and has modern energy
efficient features, the optional combustion air supply kits may
not provide all the air required to support combustion and
the proper flow of combustion gases up the chimney. The
manufacturer is not responsible for any smoking or
related problems that may result from the lack of adequate
air supply flowing into the house. It is the responsibility of
the builder/contractor to ensure that adequate air supply has
been provided for the fireplace.
12.
“Smoke free” operation is not warranted nor is the
manufacturer responsible for inadequate system draft caused
by mechanical systems, general construction conditions,
inadequate chimney heights, adverse wind conditions or
any unusual environmental conditions or factors beyond the
manufacturer’s control.
13.
When used with the Fire-Lite fireplace system, all gas
log sets must be operated with the damper clamped in the
open position. This includes unlisted “vent free” log sets.
Only listed “vent free” log sets may be operated with the
damper in the closed position.
14.
Never install an Fire-Lite fireplace component or chimney
component, or any accessory that has visible or suspected
physical damage. When in doubt about a component’s
usability consult your Isokern distributor or authorized
Isokern representative for advice.
15.
Do not alter or modify an Fire-Lite fireplace components
under any circumstances. Modification to Fire-Lite components
may void warranties, listings and approvals and could
result in an unsafe and potentially dangerous installation.
Alterations to the Fire-Lite firebox opening height and
width are not allowed without prior written approval and
instructions from Earthcore Industries, L.L.C.
16.
Wherever insulation is used, the Fire-Lite fireplace must
not be placed directly against it. Keep all insulation or vapor
barriers a minimum of three inches (3”) away from all fireplace
and chimney components.
It is recommended that insulation and vapor barriers, if
used, first be covered with gypsum board, plywood, particle
board or other material to assure that insulation and vapor
barriers remain in place.
17.
Do not pack of fill required air spaces with insulation or
other material. No material is allowed in these spaces.
18.
Never leave children unattended when there is a fire
burning in the fireplace.
19.
Burning some fuels (such as charcoal) can be hazardous
due to the possibility of producing carbon monoxide, a colorless,
odorless gas. Early signs of carbon monoxide poising
resemble flue symptoms, including headaches, dizziness or
nausea. Over exposure to carbon monoxide can lead to illness
and death.
It is strongly recommended to install smoke and carbon
monoxide alarm / detector devices wherever fireplaces are
in use.
5
Safety Instructions
Summary of Contents for FIRE-LITE series
Page 7: ...Assembled Firebox Smoke Dome Dimensions 36 42 46 7 ...
Page 23: ...23 Interior Masonry Veneer Fireplace Finishes Clearances FIGURE 38 FIGURE 36 FIGURE 37 ...
Page 28: ...DM 54 Chimney Component List Dimensions 28 ...
Page 32: ...32 DM 54 Chimney System Lateral Support cont FIGURE 51 FIGURE 52 ...
Page 51: ...51 Fire Lite Application Raised Metal Platform cont FIGURE 93 ...
Page 58: ...Notes 58 ...