Installation of the FTF-13 Metal Chimney System for the Fire-
Lite:
Transition from the Fire-Lite to the FTF-13 Metal
Chimney System:
The FTF-13 metal flue attaches to the smoke dome’s
top plate by use of the AP-ISO masonry anchor plate. The Anchor
Plate is fitted with an octagonal base plate to affix it to the smoke
dome’s top plate. The anchor plate also has starter rings for both
the inner and the outer sleeves of the metal flue (Figure 97).
Step 1.
Attach the AP-ISO anchor plate to the top plate of the
Fire-Lite by first laying a twenty-four inch (24”) square, half inch
(1/2”) thick (minimum) piece of ceramic fiber high temperature
blanket (“Inswool” Ceramic Fiber HP Blanket, rated for tempera
-
tures up to 2400 degrees F., by Harbison-Walker Refractories Co.
600 Grant Street, Pittsburgh, PA 15219, or equal.) on the top of the
top plate.
Cut a hole approximately 11” in diameter in the center of the high
temperature blanket and align the blanket on the flue hole in the
top plate (Figure 98).
Step 2.
Fit the AP-ISO Anchor Plate assembly onto the top plate
so that the inner flue sleeve projecting out the bottom of the anchor
plate is inserted through the high temperature blanket and into the
hole in the top plate. The high temperature blanket is held between
the anchor plate and the top plate as a gasket (Figure 99).
Attach Anchor Plate to the top plate with masonry attachment
screws through holes provided in the anchor plate into the top
plate. Do not over torque masonry screws into the Fire-Lite
material.
Chimney Terminations:
FTF-13 chimney pipe requires a termination component
to be installed at or near the top of the chimney chase flashing.
The FTF-13-CTD Round Termination is the
recommended termination. (See page 55)
Installation:
Step 1. Hold the FTF13-CTD over top of last chimney section.
Step 2. Center inner slip section in inner flue pipe and slip down.
Step 3. Center outer locking section over outer flue pipe.
Push down until locking tabs are firmly engaged.
Step 4. Pull up slightly on CTD to ensure locking joint has firmly
engaged.
Note:
It is recommended that all exterior exposed metal chimney
components - such as terminations, flashings, and flue - be painted
with a premium quality, high temperature, rust preventative paint
designed for metal. This is especially important when installations
are made in abnormally adverse or corrosive environments such as
near lakes and oceans or, in areas with consistently high humid
-
ity conditions. Consult the paint manufacturer’s instructions for
proper preparation and application.
Ten Foot Rule Summary:
Refer to page 40 of this manual.
FIGURE 97
FIGURE 98
FIGURE 99
FTF-13 or Equivalent Chimney System (cont.)
Summary of Contents for FIRE-LITE series
Page 7: ...Assembled Firebox Smoke Dome Dimensions 36 42 46 7 ...
Page 23: ...23 Interior Masonry Veneer Fireplace Finishes Clearances FIGURE 38 FIGURE 36 FIGURE 37 ...
Page 28: ...DM 54 Chimney Component List Dimensions 28 ...
Page 32: ...32 DM 54 Chimney System Lateral Support cont FIGURE 51 FIGURE 52 ...
Page 51: ...51 Fire Lite Application Raised Metal Platform cont FIGURE 93 ...
Page 58: ...Notes 58 ...