background image

www.ison.com.tw 

 

 

IS-C3050 WIRELESS TERMINAL User Guide 

52 

Rev 1.1 

Field

 

Field Name

 

Attribute

 

Value

 

Remarks

 

 

Message type

 

4

 

Z910

 

 

Len

 

2

 

 

 

Time Zone 

16 

Timezone 

 

 

 

 

5.3.12 Set APN 

 

The function is used to set APN of wireless terminal. 

 

 

Request message ZA00 

 

 

Field

 

Field Name

 

Attribute

 

Value

 

Remarks

 

 

Message type

 

4

 

ZA00

 

 

 

Len 

 

 

Len of APN

 

2

 

 

 

 

APN 

 

 

 

Response message ZA10 

 

Field

 

Field Name

 

Attribute

 

Value

 

Remarks

 

 

Message type

 

4

 

ZA10

 

 

Len

 

2

 

 

 

Status 

00h :OK 

01h: 

 

 

Summary of Contents for IS-C3050

Page 1: ...www ison com tw IS C3050 WIRELESS TERMINAL User Guide 1 Rev 1 1 IS C3050 Wireless Terminal User Guide ISON Basic Wireless Terminal 2G 3G Model Number IS C3050...

Page 2: ...ject to change without notice No part of this document may be reproduced or transmitted in any form or by any means electronic or mechanical including but not limited to photocopying recording transmi...

Page 3: ...www ison com tw IS C3050 WIRELESS TERMINAL User Guide 3 Rev 1 1 Revision History Version Date Description 1 0 Mar 2014 1st Release 1 1 April 2014 2nd Release 1 2 May 2015 3rd Release...

Page 4: ...Specifications 11 1 5 Precautions 12 2 MECHANICAL DESCRIPTION 13 2 1 Overview 13 2 2 Dimensions 13 3 ELECTRICAL INTERFACE DESCRIPTIONS 14 3 1 Right side view DB9 connector 14 3 2 Left side view DC Ja...

Page 5: ...www ison com tw IS C3050 WIRELESS TERMINAL User Guide 5 Rev 1 1 5 ISON Protocol 31 6 SALES CONTACT 64 7 ORDERING INFORMATION 64...

Page 6: ...ntenna Connector for IS C3050 16 Figure 6 SIM Card Holder for IS C3050 17 Figure 7 Binary Protocol Exchange 31 List of Tables Table 1 Operating Modes 10 Table 2 Features and Specifications 11 Table 3...

Page 7: ...e the status of the wireless terminal The IS C3050 wireless terminal can be used to provide a wireless communication link to many applications including metering fleet and asset management vending sec...

Page 8: ...arity None Even Odd Space Mark Flow Control RTS CTS DTR DSR Baudrate 9600 115200 selectable Serial signals TxD RxD RTS CTS DTR DSR DCD RST reset circuit GND Relay 1 output with current carrying capaci...

Page 9: ...50 consists of a fully certified CE NCC approved GSM GPRS engine SIM card holder and power regulator The wireless terminal is supplied with power via the DC jack The remaining DB9 connector are used f...

Page 10: ...d receive GPRS IDLE Module is ready for GPRS data transfer but no data is currently sent or received Power consumption depends on network settings and GPRS configuration e g multi slot settings GPRS D...

Page 11: ...1900 180mA 145mA DATA mode GPRS 2TX 3RX GSM 850 EGSM 900 GSM 1800 1900 330mA 260mA 6 Operating Temperature Normal operation 40 C to 75 C 7 Data Transfer GPRS Multi slot Class 12 max 85 6kbps Downlink...

Page 12: ...ace SIM Card Slot Supports SIM Cards 3V and 1 8V 13 Antenna 50 ohms via External SMA Connector 14 Software Reset Orderly shutdown and Reset by AT Command AT SMSO 15 RoHs All hardware components are fu...

Page 13: ...mechanical design of the wireless terminal along with the positions of the different connectors 2 2 Dimensions Figure 2 Chassis Dimension for IS C3050 S N Parameter Value 1 Height H 26 9mm 2 Length L...

Page 14: ...ide 14 Rev 1 1 3 ELECTRICAL INTERFACE DESCRIPTIONS 3 1 Right side view DB9 connector Figure 3 RS232 RS422 RS485 for IS C3050 The table below defines the RS232 RS422 RS485 pin configuration on the wire...

Page 15: ...n 2 is V When use DC for input the output power of TB is same as input power Do Not use DC PWR to be the input power at the same time it may cause damage to the equipment Relay External Relay max 48V...

Page 16: ...has to be connected to an external RF antenna matched to 50ohms Please use a SMA Male connection for the wireless terminal The table describes LED function Item Description Function 1 Power Power on...

Page 17: ...flip up type which can be locked It can be accessed through removing the battery cover as shown below Figure 6 SIM Card Holder for IS C3050 Be sure to power off the modem when user replaces the SIM c...

Page 18: ...3 5 Demo process HW installation Step 1 Please insert SIM card into SIM card holder as follows Be sure to power off the modem when user replace the SIM card Otherwise it may cause damage to the equipm...

Page 19: ...al is usually fully operational within 30 seconds after powering it up Depending on the signal strength of the network in the area logging into a network may take longer and is outside the control of...

Page 20: ...www ison com tw IS C3050 WIRELESS TERMINAL User Guide 20 Rev 1 1...

Page 21: ...ev 1 1 SW Installation Preliminary work Power on C3050 and use USB to RS232 cable to connect to C3050 PC Step 1 Open CCU ISON Cellular Configuration Utility Step 2 The main window of CCU launch Figure...

Page 22: ...C3050 WIRELESS TERMINAL User Guide 22 Rev 1 1 Item Model Shows the model user connected FW Version Current firmware version SIM Card The status of SIM Card Operator Telecoms Get Info Click it to relo...

Page 23: ...e GPRS off line event occurred C3050 will send SMS to the phone number user set DIO1 changed Tick the check box then input the phone number When the DIO1 event occurred C3050 will send SMS to the phon...

Page 24: ...of DIO changed Mode Switch Select RS232 422 485 mode by drop down list Set Baud rate Set different baud rate by drop down list Retry Time Set the retry times when connection interrupts Time Interval...

Page 25: ...op down list then the related setting page displayed Operation mode Socket TCP Mode APN Please confirm with carriers ID Set ID It supports up to 15 characters 1 IP 5 IP Multiple IP Notice When the mul...

Page 26: ...1 1 Socket UDP Mode APN Please confirm with carriers ID Set ID It supports up to 15 characters IP 1 IP 3 Multiple IP to transfer Notice When the multiple IP function is enabled with large data transmi...

Page 27: ...www ison com tw IS C3050 WIRELESS TERMINAL User Guide 27 Rev 1 1 Mobile Set the mobile number user receives SMS Send Box Input SMS text AT Command Click to switch to AT command mode...

Page 28: ...Rev 1 1 Step 4 Click Apply to save settings to C3050 When applying the setting make sure the RS232 cable is well connected If the cable is loose during the applying please long press the Reset button...

Page 29: ...and re plug the power Note This is a real operation for reference The user may input different parameters accordingly If C3050 is not running with 115200 baud rate and user want to re configure it pl...

Page 30: ...e clear 4 3 External input x2 External signal input source positive signal are DI1 and DI2 negative signal are COM_1 are COM_2 Power input range is 12V 48V it will be determined as positive It can be...

Page 31: ...wireless terminal in order to communicate with M2M devices The ISON Protocol supports Binary format exchange The host controller initiates every REQUEST RESPONSE sequence Figure 7 Binary Protocol Exc...

Page 32: ...een the wireless terminal and the Controller as shown in Table 7 Field Field Description Field Length Field type remarks 1 STX 1 B 0x02 2 Transaction type 4 A 3 Data length 2 B Size of data excluding...

Page 33: ...r this would exclude the STX but include the ETX character Link Control Characters The link control characters set are characters sets that are used by the messaging protocol as shown in Table 8 Chara...

Page 34: ...s Terminal CONFIGURATION COMMANDS The following table summarizes the configuration commands that are supported by the wireless terminal Figure 5 3 Command Command Code Response Code Management command...

Page 35: ...0 Baud rate Configuration ZA04 ZA14 Get Input status from DI1 ZA05 ZA15 Get Input status from DI2 ZA06 ZA16 Set Relay level to High ZA07 ZA17 Set Relay level to Low ZA08 ZA18 Internet command Baud rat...

Page 36: ...firmware version command is used to get wireless terminal s hardware and firmware version Request message Z100 Field Field Name Attribute Value Remarks Message type 4 Z100 Get HW FW version 1 Len 2 Re...

Page 37: ...s It s for TCP client send data function Host can send data via TCP Client service Request message Z200 Field Field Name Attribute Value Remarks Message type 4 Z200 Set TCP Client parameters Len 2 Tot...

Page 38: ...NAL User Guide 38 Rev 1 1 Response message Z210 Field Field Name Attribute Value Remarks Message type 4 Z210 Set TCP Client parameters Len 2 1 Status 1 Status 00h OK 01h ERROR 2 Error Code 1 Option If...

Page 39: ...t bridge parameter for TCP bridge services Request message Z201 Field Field Name Attribute Value Remarks Message type 4 Z201 Set TCP Transparent Bridge parameters Len 2 Total length Len 2 1 Len of IP...

Page 40: ...er Guide 40 Rev 1 1 Response message Z211 Field Field Name Attribute Value Remarks Message type 4 Z211 Set TCP Transparent Bridge parameters Len 2 1 Status 1 Status 00h OK 01h ERROR 2 Error Code 1 Opt...

Page 41: ...function Request message Z202 Field Field Name Attribute Value Remarks Message type 4 Z202 Len 2 Len of phone number 2 Phone number N For example 0926123456 Response message Z212 Field Field Name Att...

Page 42: ...message Z300 Field Field Name Attribute Value Remarks Message type 4 Z300 Set FTP Client parameters Len 2 1 Len of IP 2 2 FTP IP N FTP IP FTP server IP 3 Len of port 2 4 FTP port N FTP Port Port 5 Le...

Page 43: ...ge type 4 Z310 Set FTP Client parameters 1 Len 2 2 Status 1 Status 00h OK 01h ERROR Status of setting parameters to EEPROM Error Code 1 Option 5 3 6 Get wireless terminal Setting Profile Get IS C3050...

Page 44: ...3 Transparent IP N Transparent IP eg 175 180 133 126 65535 4 Len of IP 2 2 5 TCP IP Client IP N TCP IP Client IP eg 175 180 133 126 65535 6 Len of IP 3 2 7 FTP IP N FTP IP eg 175 180 133 126 65535 8 L...

Page 45: ...e N Reserved service eg 175 180 133 126 65535 16 Len of IP 8 2 17 Reserved service N Reserved service eg 175 180 133 126 65535 18 Len of IP 9 2 19 Reserved service N Reserved service eg 175 180 133 12...

Page 46: ...0 Set wireless terminal profile 1 Total Len 2 2 Len of IP 1 2 3 Transparent IP N Transparent IP eg 175 180 133 126 65535 4 Len of IP 2 2 5 TCP IP Client IP N TCP IP Client IP eg 175 180 133 126 65535...

Page 47: ...ed service N Reserved service eg 175 180 133 126 65535 16 Len of IP 8 2 17 Reserved service N Reserved service eg 175 180 133 126 65535 18 Len of IP 9 2 19 Reserved service N Reserved service eg 175 1...

Page 48: ...Error Code 1 option 5 3 8 Get wireless terminal 3G Signal Quality Get wireless terminal 3G signal quality the RSSI value Request message Z600 Field Field Name Attribute Value Remarks Message type 4 Z...

Page 49: ...ok then wireless terminal can operate in normal mode Request message Z700 Field Field Name Attribute Value Remarks Message type 4 Z700 Get SIM Status 1 Len 2 B Response message Z710 Field Field Name A...

Page 50: ...unction is used to get operation name Request message Z800 Field Field Name Attribute Value Remarks Message type 4 Z800 Get operation name 1 Len 2 Response message Z810 Field Field Name Attribute Valu...

Page 51: ...00h OK 01h ERROR 00 enable ok 01 enable with ERROR If ERROR occurs please use Get Error code command to see which error occurs Error Code 1 option 5 3 11 Get Time Zone The function is used to get tim...

Page 52: ...0 1 Len 2 2 Time Zone 16 Timezone 5 3 12 Set APN The function is used to set APN of wireless terminal Request message ZA00 Field Field Name Attribute Value Remarks Message type 4 ZA00 Len 2 1 Len of A...

Page 53: ...Error Code 5 3 13 Baudrate Configuration Set baud rate of IS C3050 Request message ZA04 Field Field Name Attribute Value Remarks Message type 4 ZA04 1 Len 2 2 Baud rate parameter 1 D2 230400 D3 115200...

Page 54: ...Attribute Value Remarks Message type 4 ZA14 1 Len 2 2 Status 1 00h OK 01h ERROR Error Code 1 Option 5 3 14 Get Input Status from DI1 This command will get external input status from DI 1 interface Re...

Page 55: ...ut Status 1 00h Low 01h High 5 3 15 Get Input Status from DI2 This command will get external input status from DI2 interface Request message ZA06 Field Field Name Attribute Value Remarks Message type...

Page 56: ...evel to High Set RELAY output to high Request message ZA07 Field Field Name Attribute Value Remarks Message type 4 ZA07 1 Len 2 2 Set Relay to High 1 48h High Response message ZA17 Field Field Name At...

Page 57: ...Level to Low Set RELAY output to low Request message ZA08 Field Field Name Attribute Value Remarks Message type 4 ZA08 1 Len 2 2 Set Relay to High 1 4Ch Low Response message ZA18 Field Field Name Attr...

Page 58: ...or devices can send data they would like to send Request message ZC00 Field Field Name Attribute Value Remarks Message type 4 ZC00 1 Len 2 Response message ZC10 Field Field Name Attribute Value Remar...

Page 59: ...isable Transparent TCP bridge services Request message ZC01 Field Field Name Attribute Value Remarks Message type 4 ZC01 1 Len 2 Response message ZC11 Field Field Name Attribute Value Remarks Message...

Page 60: ...ield Field Name Attribute Value Remarks Message type 4 ZC02 1 Len 2 Len of SMS message 2 SMS Message N Response message ZC12 Field Field Name Attribute Value Remarks Message type 4 ZC12 1 Len 2 2 Stat...

Page 61: ...hen issue the Send TCP Data function the wireless terminal will send TCP data to server depend on TCP setting parameters Request message ZD00 Field Field Name Attribute Value Remarks Message type 4 ZD...

Page 62: ...com tw IS C3050 WIRELESS TERMINAL User Guide 62 Rev 1 1 Response message ZD10 Field Field Name Attribute Value Remarks Message type 4 ZD10 1 Len 2 2 Status 1 00h OK 01h ERROR 00 ok 01 ERROR Error Code...

Page 63: ...meters and restart the device Request message ZF10 Field Field Name Attribute Value Remarks Message type 4 ZF10 1 Len 2 Response message ZF20 Field Field Name Attribute Value Remarks Message type 4 ZF...

Page 64: ...uct IS C3050 The ISON Dual Band 2G 3G wireless terminal Power Adaptor ISA PSP 100 Input AC 100 240V Output 9V 1 3A DC jack 5 5 2 1 ISA PSP 101 US Adapter Plug ISA PSP 104 British Adapter Plug ISA PSP...

Reviews: