10
How to Install the ISONAS PureIP Reader-controller
1.6
: PURE IP READER-CONTROLLER RESET BUTTON
The Pure IP Reader-Controller has a Reset Button located on the back. It can be used for two
different types of resets.
It is helpful if the Pure IP Reader-Controller’s Ethernet cable is connected, and functioning (the
network status LED is lit). Monitoring the RC04’s main status LED allows you to determine the
status of the reset operation.
Reset CPU: Press, hold (approx. 2 seconds) and release the Reset button. Once the Reset
Button is released, the reader should reboot. The main Status LED should turn AMBER, and
then return to the normal RED state. If the LED does not turn AMBER, then the reset did not
occur.
Reset Configuration: Press and hold the Reset button (approx. 10 seconds), until the
RC04’s Main Status LED turns AMBER. Selected reader-controller configuration settings are
reset to factory defaults. Setting that are changed include:
DHCP
(Default value:
On)
IP Address
(Default value:
192.168.254.119)
IP Port
(Default value:
10001)
Subnet Mask
(Default value:
255.255.0.0)
Gateway
(Default value:
0.0.0.0)
ACS Alias
(Default value:
{blank})
ACS Server IP
(Default value:
0.0.0.0)
Communication Type
(Default value:
Client)
Remote Host Name
(Default value:
{blank})
Remote Host IP
(Default value:
0.0.0.0)
Remote Host IP Port
(Default value:
55533)
Remote Host DNS
(Default value:
8.8.8.8)
HID Prox Enabled
(Default value:
On)
HID Bit Mask
(Default value:
“FFFFFF”)
Clear AES Encryption Configuration
Reset Pure IP Reader-Controller’s Passwords