background image

 

__________________________________________________________________________________ 

8 | 

P a g e - S e i t e

 

 

Operation 

 
Prior to connection of the product, please 
ensure that the supply voltage matches the 
product data label or the product 
specifications out of the accompanied 
documents, respectively. 
 

 Any product must be temperature 

 

  controlled! (unless otherwise stated 

 

  or specified) 

 

When connecting the product, the 
requirements of the standards listed below in 
“General Safety Instructions” and “Additional 
Safety Instructions” have to be observed. 
The maximum operating and withstand 
temperature for the product are listed in the 
technical data section. . It has to be ensured 
that this temperature is never exceeded at 
any point of the product, irrespective of 
whether it is switched on or off. 
 
In cases in which the kind of installation or 
application cannot exclude that the maximum 
product temperature is exceeded, a suitable 
device for temperature control and, if 
necessary, for temperature limitation has to 
be provided.  
Proper operation of the temperature 
controlling and limiting devices has to be 
checked at initial operation. 
 

 Note: 

Products of woven glass or silica-glass fabric 
designs are flexible due to chemical processes 
and additives that help stabilizing and 
softening the fabrics. At increasing 
temperatures these additives are dissolving 
(see De-sizing for more details). The loss of 
additives results in decreasing stability 
between the fibers and reduces the flexibility 
of the product. If properly installed and fixed 
for steady installation the products 
performance does not get influenced by the 
de-sizing of the material.  
 

Be aware that in cases of dismantling for 
revision of the system and re-installation 
these products may fail operation due to loss 
of stability and must be replaced. If you are 
having doubts or need of assistance for your 
special application please contact us. (see last 
page for contact information) 
 

De-sizing: 

Owing to technical reasons, some smoke or 
vapors will develop at certain heating 
temperatures during initial operation of fabric 
woven materials. This is caused by the heat-up 
of the size (slipping / binding or cross-linking 
agent). The emerging vapors are harmful and 
should not be inhaled. 
 

 

Please permit good ventilation 

during this de-sizing phase!

 

 

Maintenance and Safety 

 
Maintenance and Safety is performed 
according to the standards listed under 
"General Safety Instructions” and “Additional 
Safety Instructions”, the regulations of the 
employer's liability insurance associations 
applicable to the respective way of use, as 
well as other relevant rules applying to the 
application. The operation of the system 
should be checked for correct functionality. 
The electrical supply should be checked to 
ensure it conforms to the system design 
documentation. 
At least once per year the function of the 
temperature controlling and temperature 
limiting safety device has to be checked and 
the surface and connection line should be 
inspected for visible damage. 
Warning labels and identification labels should 
be clearly visible, intact and able to display the 
correct information. Products which show 
exposed heating conductors or wires, were 
overheated. These products have to be 
immediately put out of operation and to be 
secured against reuse. 

Summary of Contents for IT-G Series

Page 1: ...1235 OMH58591 R18 0 OPERATING INSTRUCTIONS BEDIENUNGSANLEITUNG HEATING TAPES HEIZB NDER SERIES SERIE IT S20 IT S45 IT G IT G25 IT ITH IT H...

Page 2: ...6 Installation 7 Operation 8 Maintenance and Safety 8 Malfunction and Excessive Strain 9 Heated Media 9 Technical Data 10 DEUTSCH 11 Allgemeine Sicherheitshinweise 11 Allgemeine Produkt Informationen...

Page 3: ...ance with any applicable specification _____________________________________________________________________________________________________ Haftungsauschluss Wichtig Alle Angaben einschlie lich der A...

Page 4: ...ance with these standards ELECTRICAL EQUIPMENT These products represent electrical equipment To prevent from danger caused by electric energy an earth leakage current breaker ELCB or RCD has to be ins...

Page 5: ...sulation Woven structural braids Layers of metallic braid Additional temperature sensors and or thermal protectors Additional controllers various operating voltages and performance ratings They are us...

Page 6: ...t between the product and the surface of the component to be heated Do not overlap Do not use for any other purpose than intended Product Design The products consist of resistance heating wire which a...

Page 7: ...atures are not exceeded Please refer to technical data section for information 9 Never stick needles or sharp objects or the like in the product 10 The product should be protected against mechanical d...

Page 8: ...nstallation the products performance does not get influenced by the de sizing of the material Be aware that in cases of dismantling for revision of the system and re installation these products may fa...

Page 9: ...on operating temperature Heated Media The product must not be used to heat explosive media or media developing explosive gases when heated The product must only be installed outside hazardous location...

Page 10: ...element var alloys var alloys var alloys NiCr Electrical Insulation Glass fiber Glass fiber Glass fiber Silica Glass fiber Outer Sheath Ni plated Cu Glass fiber Glass fiber Silica Glass fiber Structu...

Page 11: ...erfolgen ELEKTRISCHES BETRIEBSMITTEL Das Produkt ist ein elektrisches Betriebsmittel Um Gefahren durch elektrischen Strom vorzubeugen darf es nur ber einen Fehlerstrom Schutzschalter mit einem Ausl se...

Page 12: ...be Isolation Strukturellen Geweben Zus tzliche Temperaturf hler und oder w chter Zus tzlichen Regelger ten unterschiedlichen Betriebsspannungen und Leistungsparametern Sie werden zum Aufheizen Tempera...

Page 13: ...geschultem fach und sachkundigem Personal durchzuf hren Bei der Montage muss darauf geachtet werden dass berall ein guter Kontakt zwischen Heizband und der zu beheizenden Komponente vorliegt Montieren...

Page 14: ...onierten Zuleitungen und Heiss Kalt Verbindungen sollten so montiert installiert werden das Ihre zul ssige Einsatztemperatur nicht berschritten wird Informationen hierzu finden Sie in dem Abshcnitt te...

Page 15: ...chtungen zu pr fen Die geforderten Pr fungen gem den unter Allgemeine Sicherheitshinweise genannten Normen sind nach Fertigstellung der Elektrow rmeanlage oder Einrichtung durchzuf hren und zu dokumen...

Page 16: ...tem Personal im Herstellerwerk oder von durch den Hersteller ausdr cklich autorisierten Unternehmen vorgenommen Bei R cksendungen bitten wir darum das Produkt generell vorher zu Dekontaminieren dies s...

Page 17: ...Produkt von regul rem Gewerbe Haushaltsm ll getrennt entsorgt werden sollte Es liegt in Ihrer Verantwortung dieses Produkt und andere elektrische und elektronische Produkte nur ber die gesetzlich vorg...

Page 18: ...ver Leg NiCr Elektrische Isolation Glasfaser Glasfaser Glasfaser Silikat Glasfaser Aussenschutz Cu vz Glasfaser Glasfaser Silikat Glasfaser Tr germaterial Glasfaser Glasfaser Glasfaser Silikat Glasfa...

Page 19: ...mit der den folgenden Norm en oder normativen Dokumenten bereinstimmt auquel cette d claration se rapporte est conforme aux norme s ou aux documents normatifs suivants Terms of the Directive s and Ap...

Page 20: ...Thermocoax Isopad GmbH Englerstrasse 11 D 69126 Heidelberg Germany Tel 49 0 6221 3043 0 Fax 49 0 6221 3043 956 Mail to isopad info thermocoax com Web www thermocoax com www isopad com _______________...

Reviews: