background image

 

__________________________________________________________________________________ 

5 | 

P a g e - S e i t e

 

 

  

ATTENTION! HOT! 

These products contain electrical heating 
elements. Never touch in case of hot surface of 
the product or when the product is in operation. 
This affects also all metallic parts, which can 
reach high temperature during operation. There 
is danger of combustion. 
 

 

INFLAMMATION AND EXPLOSION RISK! 

The product is not explosion-proof. It should 
never be integrated into tempering processes 
where liquids handled may support explosions. 
This covers also applications where gas/air-
mixtures may occur. The product must not be 
used to heat explosive media or those 
developing explosive gases when heated. The 
product must be installed only outside of 
hazardous locations. 
 

General Product Information 

 
The products consist of Polymer insulated 
heating cables for industrial use. Depending on 
the requirement they are designed with the 
following features: 
 
-

 

Various alloys of resistance heating wires 

-

 

Layers of Polymer Insulation 

-

 

Additional Layers of metallic braid 

-

 

Additional temperature sensors and/or 
thermal protectors 

-

 

Additional controllers 

-

 

various operating voltages and performance 
ratings 

 
They are used to heat-up, maintain and 
compensate heat losses internally and externally 
on refrigeration draining line systems and 
freezer doors. The maximum admissible product 
temperature varies in design and in the different 
insulation material. The maximum achievable 
withstand temperature, however, depends on 
the specific operating conditions. It may be 
influenced by the heat conductivity of the 
materials and media to be heated as well as by 

the throughput, the ambient temperature, the 
insulating material and the insulation thickness. 
ISOPAD offers a standard range of different 
versions but also versions tailored 
(manufactured to desired length) individually to 
the application. 
 

  Note: 

For individual specifications please refer to the 
product label or type plate. In the case of 
installation difficulties or special requirements it 
is recommended to discuss and agree suitable 
installation procedures. In case of doubt or if 
necessary please contact us. (see last page for 
contact information) 
 

Additional Safety Instruction 
(product related) 

 

  Attention! 

When using electric surface heating 
equipment, basic safety precautions should be 
followed in order to prevent the occurrence of 
burns, electric shock, fire or injury to persons 
or animals. 
 
The following safety notes have to be followed: 

 

 

-

 

The products must not be used on plastic 
or other non-metallic surfaces. 

-

 

The products are not suitable for use in 
applications where they may be subject to 
aggressive chemicals. 

-

 

Prior to connecting the heating to mains, 
please ensure that the mains voltage 
matches that indicated on the label. 

-

 

Check the suitability of the product for the 
maximum withstand temperature both 
energized and de-energized (refer to the 
Technical Data in this manual and on the 
label). 

-

 

Care must be taken not to damage the 
product during installation. 

-

 

The product is electrical equipment. It 
must therefore be operated only by 
properly trained staff.  

Summary of Contents for IT-KDL-SL

Page 1: ...1235 OMH58595 R18 0 OPERATING INSTRUCTIONS BEDIENUNGSANLEITUNG HEATING TAPES HEIZB NDER SERIES SERIE IT KDL...

Page 2: ...intenance and Safety 8 Malfunction and Excessive Strain 9 Heated Media 9 Technical Data 9 Ordering Information 11 DEUTSCH 12 Allgemeine Sicherheitshinweise 12 Allgemeine Produkt Informationen 13 Weite...

Page 3: ...ance with any applicable specification _____________________________________________________________________________________________________ Haftungsauschluss Wichtig Alle Angaben einschlie lich der A...

Page 4: ...aker ELCB or RCD has to be installed for protection purpose This ELCB should represent a tripping current of 30mA To guard against electric shock the products have to be maintained and services by aut...

Page 5: ...um achievable withstand temperature however depends on the specific operating conditions It may be influenced by the heat conductivity of the materials and media to be heated as well as by the through...

Page 6: ...rlapping or shortage when installed The different versions vary in design which can be seen In the next section For your individual application or product selection assistance please contact us see la...

Page 7: ...roduct is not excessively stressed or strained during installation For minimum bending radius and spacing information refer to the technical data section 4 When installing the product make sure that i...

Page 8: ...trolled unless otherwise stated or specified When connecting the product the requirements of the standards listed below in General Safety Instructions and Additional Safety Instructions have to be obs...

Page 9: ...on operating temperature Heated Media The product must not be used to heat explosive media or media developing explosive gases when heated The product must only be installed outside hazardous location...

Page 10: ...cing 10 mm 10 mm Protection Class II I II I IP Rating IP67 IP67 Heating element var alloys var alloys Electrical Insulation Silicone rubber Silicone rubber Outer Sheath Silicone rubber Silicone rubber...

Page 11: ...IT KDL SL 3M 120W 230V 421844 000 160 4 0 IT KDL SL 4M 160W 230V 311936 000 200 5 0 IT KDL SL 5M 200W 230V 159372 000 240 6 0 IT KDL SL 6M 240W 230V 778676 000 Type IT KDL SR Power Heated Length Item...

Page 12: ...CHES BETRIEBSMITTEL Das Produkt ist ein elektrisches Betriebsmittel Um Gefahren durch elektrischen Strom vorzubeugen darf es nur ber einen Fehlerstrom Schutzschalter mit einem Ausl sestrom von 30mA in...

Page 13: ...tion Lagen mit metallischem Schutzgeflecht Zus tzliche Temperaturf hler und oder w chter Zus tzlichen Regelger ten unterschiedlichen Betriebsspannungen und Leistungsparametern Sie werden zum Aufheizen...

Page 14: ...her in Polymer Isolation eingebettet ist Die Aussenschutz schicht ist ebenfalls aus Polyemer Zus tzlich kann ein Metallgeflecht zum mechanischen oder elektrischen Schutz verwendet werden Das Produkt i...

Page 15: ...en wir Ihnen gerne zur Verf gung 2 Die Oberfl che des Objektes muss trocken und sauber fettfrei sein Sie darf nicht beschichtet sein 3 Achten Sie darauf das Produkt w hrend der Installation nicht extr...

Page 16: ...t die bereinstimmung der Netzspannung mit dem Typenschild oder der gelieferten Spezifikation zu berpr fen Jedes Produkt nur temperaturgeregelt betreiben falls nicht anderweitig spezifiziert Beim Ansch...

Page 17: ...dies schriftlich zu best tigen und dem Produkt als Information beizulegen Wenn Sie eine Dekontaminationsvorlage ben tigen nehmen Sie dazu bitte Kontakt mit uns auf Fehler und au ergew hnliche Belastu...

Page 18: ...Produkt von regul rem Gewerbe Haushaltsm ll getrennt entsorgt werden sollte Es liegt in Ihrer Verantwortung dieses Produkt und andere elektrische und elektronische Produkte nur ber die gesetzlich vorg...

Page 19: ...egeabstand 10 mm 10 mm Schutzklasse II I II I Schutzart IP67 IP67 Heizelement ver Legierungen ver Legierungen Elektrische Isolation Silikon Silikon Aussenmantel Silikon Silikon Kupfer Nickel Geflecht...

Page 20: ...IT KDL SL 3M 120W 230V 421844 000 160 4 0 IT KDL SL 4M 160W 230V 311936 000 200 5 0 IT KDL SL 5M 200W 230V 159372 000 240 6 0 IT KDL SL 6M 240W 230V 778676 000 Typ IT KDL SR Leistung Beheizte L nge A...

Page 21: ...__________________________________________________________________________________ 21 P a g e S e i t e Notes Notizen __________________________________________________________________________________...

Page 22: ...__________________________________________________________________________________ 22 P a g e S e i t e Notes Notizen __________________________________________________________________________________...

Page 23: ...ng bezieht mit der den folgenden Norm en oder normativen Dokumenten bereinstimmt auquel cette d claration se rapporte est conforme aux norme s ou aux documents normatifs suivants Terms of the Directiv...

Page 24: ...2018 THERMOCOAX ISOPAD 1235 OMH58595 R18 0 Thermocoax Isopad GmbH Englerstrasse 11 D 69126 Heidelberg Germany Tel 49 0 6221 3043 0 Fax 49 0 6221 3043 956 Mail to isopad info thermocoax com Web www th...

Reviews: