In case of additional safety matters a
temperature limiting device may be installed
to protect the application components from
damage.
To prevent danger an RCD or ELCB
has to be installed!
Caution:
To avoid external touching and damage, it is
required that within the application the product
(component) has to be covered by a metal
sheeting or braid, which has to be included in
the protective arrangement of Protection Class I
(protective earth) according to VDE0100 or to
the relevant standards in your country and is to
be taken into consideration. Metallic
components coming in contact with the product
have to be incorporated in the protection
measures of Protection
Class I (protective earth). For details please refer
to the standard VDE 0100 (Germany) or the
relevant standards in your country.
Additional to these instructions special
requirements for the specific products are found
on the product label or type plate and must be
followed as well.
The products are designed at a certain
protection class. Considering that the product is
not protected against hazardous body currents,
it has to be installed in such a manner that any
risk is excluded.
In case of doubt or if necessary please contact
us. (see last page for contact information)
Operation
Prior to connection of the product, please
ensure that the supply voltage matches the
product data label or the product specifications
out of the accompanied documents,
respectively.
Any product must be temperature
controlled! (unless otherwise stated or
specified)
When connecting the product, the requirements
of the standards listed below in “General Safety
Instructions” and “Additional Safety
Instructions” have to be observed. The
maximum operating and withstand temperature
for the product are listed in the technical data
section. It has to be ensured that this
temperature is never exceeded at any point of
the product, irrespective of whether it is
switched on or off. In cases in which the kind of
installation or application cannot exclude that
the maximum product temperature is exceeded,
a suitable device for temperature control and, if
necessary, for temperature limitation has to be
provided. Proper operation of the temperature
controlling and limiting devices has to be
checked at initial operation.
Maintenance and Safety
Maintenance and Safety is performed according
to the standards listed under "General Safety
Instructions” and “Additional Safety
Instructions”, the regulations of the employer's
liability insurance associations applicable to the
respective way of use, as well as other relevant
rules applying to the application. The operation
of the system should be checked for correct
functionality. The electrical supply should be
checked to ensure it conforms to the system
design documentation.
At least once per year the function of the
temperature controlling and temperature
limiting safety device has to be checked and the
surface and connection line should be inspected
for visible damage.
Warning labels and identification labels should
be clearly visible, intact and able to display the
correct information. Products which show
exposed heating conductors or wires, were
overheated. These products have to be
immediately put out of operation and to be
secured against reuse.