background image

15 

(6) Diode Check

 

Range 

Resolution 

Accuracy 

Max.Test  

Current 

Max.Open 

Circuit voltage 

 

<

 

1mV 

±(1.5%r 5digits) 

1.5mA 

3.2V 

* For 0.4V ~ 0.9V 

Overload Protection : 

600V d.c./a.c. max. 

Continuity :  

Internal sounder operates when resistance is less than 50

Ω

 

(7) Auto Power Off 

 
The meter will automatically shut itself off after approximately 30 minutes after power on. 

The meter can be turned back on by switching to another range. 

Summary of Contents for IDM93N

Page 1: ...INSTRUCTION MANUAL IDM93N DIGITAL MULTIMETER EN FR IT DE...

Page 2: ...1 ISO TECH IDM93N DIGITAL MULTIMETER INSTRUCTION MANUAL...

Page 3: ...2...

Page 4: ...L ARE FOR USE BY QUALIFIED PERSONNEL ONLY TO AVOID ELECTRIC SHOCK DO NOT PERFORM ANY SERVICING OTHER THAN THAT CONTAINED IN THE OPERATING INSTRUCTIONS UNLESS YOU ARE QUALIFIED TO DO SO TO AVOID ELECTR...

Page 5: ...from its packing you should have the following items 1 Digital Multimeter 2 Test lead set one black one red 3 Instruction Manual 4 Protective holster 1 2 Meter Safety Terms marked on Equipment ATTENTI...

Page 6: ...the meter s front panel controls and connectors 1 Digital Display The digital display has a 3 1 2 digit LCD readout maximum reading 1999 with automatic polarity decimal point overrange and low battery...

Page 7: ...r current measurements up to 200mA 6 10A Input Terminal Positive input connector for current measurements up to 10A 7 Capacitor Test Input terminals Used for capacitance measurements 8 AC DC Switch Se...

Page 8: ...7 1 6 5 3 4 7 2 8 Figure 1...

Page 9: ...are observed Display 3 1 2 digit Liquid Crystal Display LCD with a maximum reading of 1999 Polarity Indication Automatic positive implied negative indicated Overrange Indication 1 or 1 Low Battery In...

Page 10: ...ster Accessories Protective Holster battery installed and instruction manual 2 2 Environmental Conditions Indoor Use Maximum Altitude 2000 meters Installation Category IEC 1010 600V CAT II 300V CAT II...

Page 11: ...uracy is reading number of digits at 23 C 5 C less than 75 R H 1 DC Volts Range Resolution Accuracy Over voltage protection 200mV 100 V 0 5 reading 1digit 2V 1mV 20V 10mV 200V 100mV 600V 1V 600V d c o...

Page 12: ...on Accuracy Over voltage protection 200mV 100 V 1 3 reading 4digits 40Hz to 500Hz 2V 1mV 20V 10mV 200V 100mV 600V 1V 600V d c or 600 V a c rms AC Conversion Type Average Sensing rms indication Input I...

Page 13: ...n Accuracy Voltage Burden 200 A 0 1 A 1 0 reading 1digit 600mV max 2mA 1 A 20mA 10 A 200mA 100 A 10A 10mA 2 0 reading 3digits 900mV max Overload Protection 1A 415V fast blow fuse for mA A input 10A 41...

Page 14: ...A 1 5 reading 3digits 40Hz 500Hz 600mV rms max 2mA 1 A 20mA 10 A 200mA 100 A 10A 10mA 2 5 reading 7digits 40Hz 500Hz 900mV rms max AC Conversion Type Average sensing rms indication Overload Protection...

Page 15: ...Accuracy Max Test Current Max Open Circuit Voltage 200 0 1 0 8 reading 4digits 2 5mA 3 2V 2K 1 0 8 reading 1digit 200 A 20K 10 40 A 200K 100 4 A 20M 10K 1 5 reading 5digits 40nA 0 5V 2M 1K 400nA Over...

Page 16: ...its 1 5mA 3 2V For 0 4V 0 9V Overload Protection 600V d c a c max Continuity Internal sounder operates when resistance is less than 50 7 Auto Power Off The meter will automatically shut itself off aft...

Page 17: ...16 8 Capacitance Range Resolution Accuracy Test Frequency 2nF 1pF 40Hz 20nF 10pF 200nF 100pF 2 F 1nF 200 F 100nF 2 0 reading 4digits 20 F 10nF...

Page 18: ...Counter Range Resolution Accuracy 5Vrms Max Sensitivity Min Input Frequency Overload Protection 2K Hz 1 Hz 1 0 reading 3digits 200m Vrms min 20 Hz 20K Hz 10 Hz 200 Hz 200K Hz 100 Hz 20K Hz 600V d c o...

Page 19: ...safe condition TEST EQUIPMENT RISK ASSESSMENT Users of this equipment and or their employers are reminded that health and safety legislation require them to carry out valid risk assessments of all el...

Page 20: ...or indicate incorrect measurement values 4 Maximum rated voltage to earth for voltage and current measurements terminals is 600V AC DC CAT II 300V AC DC CAT III 3 2 Voltage Measurements 1 Set the rot...

Page 21: ...e required position 3 Connect black test lead to COM terminal 4 Connect red test lead to A mA terminal for measurements up to 200mA For measuring current between 200mA and 10A connect red test lead to...

Page 22: ...ctive 000 short circuit or 1 non conductance is displayed Reverse Check of Diode If the diode under test is good 1 is displayed If the diode under test is defective 000 or other values are displayed 3...

Page 23: ...ver apply voltage to the Capacitor Test input terminals as this may damage the instrument 4 Insert the capacitor into input terminals and read the displayed value 3 8 Frequency Measurement 1 Set the r...

Page 24: ...oided as far as possible and if inevitable shall be carried out by a skilled person who is aware of the hazard involved Whenever it is likely that the protection has been impaired the instrument shall...

Page 25: ...hree screws from the case bottom 4 Lift the end of the case bottom until it gently unsnaps from the case top at the end nearest the LCD Lift the battery from the case top and carefully disconnect the...

Page 26: ...he fuse out of the fuse holder 4 Install a new fuse of the same size and rating Make sure the new fuse is centered in the fuse holder 5 Make sure that the case top rotary switch and the circuit board...

Page 27: ...26 Case Bottom Case Top 9V Battery Battery Connector Fuse 2 Fuse 1 Figure 2A Figure 2B Battery and Fuse Replacement Case Bottom Case Top...

Page 28: ...27 HOW TO USE THE PROBE HOLDER Clip one probe on the holster for one handed meter operation Wrap the leads around the holster to store the test probes...

Page 29: ...28 HOW TO USE THE TILT STAND AND HOLSTER Swing the stand out for easier meter reading Swing the upper holder out and hook it over a door...

Page 30: ...29 HOW TO USE THE TILT STAND AND HOLSTER Meter in holster face down Hang on a nail at the workbench...

Page 31: ...nited Kingdom Japan West Tower 12th Floor Yokohama Business Park 134 Godocho Hodogaya Yokohama Kanagawa 240 0005 Japan USA 7410 Pebble Drive Fort Worth Texas 76118 6961 Canada 1701 Woodward Drive Ste...

Reviews: