MEASUREMENT AND ASSEMBLY MANUAL
Validity of the manual: 1. 6. 2017
21
in order to mount the box more securely if you do not wish to
use mounting brackets. Make sure the mounting screws
cannot damage the fabric.
to finish or seal the gap between the box and the wall.
5.4. FITTING THE 30X20X2 MM ANGLED PROFILE FOR THE BOTTOM SLAT
This angled profile is intended to be fitted at the bottom on the window board or sill so that the bottom slat can drop neatly
behind this angled profile. When the gap between the angled profile and the window board has been properly sealed with
silicone caulk, the screens will serve as an excellent black-out shade.
6. TROUBLESHOOTING AND REPAIRS
6.1. THE SCREEN WILL NOT ROLL UP OR DOWN:
The limit switches inside the motor have not been calibrated in either direction. Push in both calibration buttons
and proceed with the setting of the limit switches.
The motor cable has been extended and there is a poor connection. Check the connections.
The motor has overheated and the thermal protection has shut it off. Allow it to cool for a half hour.
Incorrect calibration of the limit switches.
No voltage at the switch. Check with a voltmeter.
Motor is not connected correctly. Check the wiring diagram.
6.2. THE MOTOR HUMS:
Check whether everything can move freely in both directions. Is anything jammed?
The motor capacitor is burned out (due to incorrect motor connection).
The motor is not connected correctly: check the connection of motor cables to the switch using the diagram
mentioned above. A phase wire (brown or black) has been exchanged with the neutral wire (blue). The motor
does run in one direction, but it only hums when run in the other direction.
6.3. THE MOTOR DOES NOT STOP IN TIME:
Incorrect calibration of limit switches.
fig.
37