MEASUREMENT AND ASSEMBLY MANUAL
Validity of the manual: 1. 9. 2014
1
SYSTEM 25
1. MEASUREMENTS
THE WIDTH AND HEIGHT ARE MEASURED IN THE FOLLOWING MANNER:
W
…… (width)
is measured closely at the glass from the left inside edge of the glazing bar to the right edge of the glazing
bar, including any rubber or silicon sealing. Measurements are taken at three points in the window wing: on the top, in the
middle, the bottom and for production and ordering of the blind then the minimum measured dimension is used. The
standard width of the SYSTEM 25 blind is written in below chart,
with a tolerance of ± 1 mm. It is recommended to consult
with the manufacturer for dimensions outside the stated limits.
H
…… (height)
is measured the same as the width in three points, including sealing. However, in this case the maximum
measured dimension is used and is written into the order form. The standard height of the SYSTEM25 blind is written in
below chart, with a tolerance of +20 mm. It is recommended to consult with the manufacturer for dimensions outside the
stated limits.
Type of product
Width (from - to, mm)
Height (from
– to, mm)
Max. guaranteed area (m
2
)
System25 cord
300
– 2000
300
– 2200
2,5
System25 chain
300
– 2000
300
– 2200
2,5
System25 handle
300
– 2000
300
– 2200
2,5
System25 tex. tape motor
400
– 2000
300
– 2200
4,4
System25 cord motor
600 - 2000
300
– 2200
4,4
W
H