MEASUREMENT AND ASSEMBLY MANUAL
Validity of the manual: 1. 9. 2014
2
D
…… (depth)
depth of the glazing bar is measured in relation to the use of the distance pads under the plastic holders of
the blinds. Left and right bases are not distinguished, depth of the window:
20 mm and more no base
16
– 20 mm one base for each side
12
– 16 mm two bases for each side
ATTENTION!. When measuring, check the shape and size of the glazing bar to prevent any problems during assembly of
the guiding (tightening pins or fixed console).
2. ASSEMBLY
Assemble exactly according to this manual to prevent redundant assembly errors and other related problems.
AIDS FOR ASSEMBLY:
•
electric drill, drills, cross-head screwdriver, knife, scissors, pliers
For all wooden windows, the holes must be pre-drilled for the bolts, otherwise, there is a risk of cutting the glazing bar. The
diameters of drills and types of screws are in the following table:
screw
drill with the diameter Ø
for fixation of the blind with the cover profile
3,9x16, 3,9x25
3 mm
for fixing the holder of the chain
3,9x16
3 mm
hole for tightening pin
3,2 mm for plastic and Al windows
3 mm for wooden windows
for fixation of the blind with the cover profile
3,9x16
3 mm
for fixing the holder of the chain
3x12, 3x20
2 mm
hole for tightening pin
3,2 mm for plastic and Al windows
3 mm for wooden windows
INSPECTION:
•
before assembly we recommend inspecting all the parts after the delivery of the goods to prevent any problems. The
manufacturer must be notified of any defects or comments concerning the assembly or blinds.
ASSEMBLY WITH COVER PROFILE (CONSTRUCTION - CHAIN, CORD, HANDLE, ENGINE)
•
remove the upper cover profile (if mounted on the grid)
•
on the blind in the window wing check if its dimension corresponds to the width of the window; check that the control
mechanism is on the right side. If it is necessary to be changed, it is not possible to change it for any System 25 blind.
In this case, we recommend contacting the producer. Depending on the depth and shape of the glazing bar, support
the blind using the pads. Place the blind to the window wing and screw each holder, using the two screws, into the
glazing bar to prevent damage to the frame. The holders are attached to the upper profile in production to ensure the
correct position during assembly of the blind on the window wing. If the blind is fitted with a brake (only in the version
with a chain) there is a plastic holder between the gearbox and the brake which decreases the control force of the blind
and prevents deformation. For the version with the handle, proceed similarly. By locating the holder closely behind the