background image

 

 
 
               

SPECIFICATIONS 

 

System 
Frequency Range   

 

30 Hz 

– 100 Hz 

Frequency Response (-3 dB) 

38 Hz 

– 100 Hz 

Peak Output @ 1m   

 

126 dB SPL 

Crossover Point 

 

 

100 Hz (24 dB per Octave) 

Input Type   

 

 

Balanced differential 

Input Impedance 

 

 

10K ohms 

Thermal Protection 

Output Drivers have internal protection, self resetting.  Heatsink 
temperature monitored and input is muted if safe temperature is exceeded, 
self-resetting.  Transformer has internal thermal fuse, self-resetting. 

 
Transducer 
 Low-Frequency Transducer 
 

Diameter 

 

 

18” (381mm) 

 

Voice Coil Diameter 

 

4” (76.2mm) 

 

Power Handling  

             500 watts RMS 

 

D-CAT Technology 

Power Amplifier 

Low-Frequency Amplifier 
   Power Output / Stand-Alone 

600 watts RMS 

   Power Output with SP118-SP115  900 watts RMS 
   THD 

 

 

 

0.06% typical 

 
Line Input Power 
 

Voltage  

 

            117VAC, 60 Hz 

 

Current  

 

             6.9 amps 

 

Power   

 

 

800 watts 

 
Physical 
Height 

 

 

            

32.5” (825mm) 

Front Width  

                         

24”    (609mm) 

Depth 

 

 

            

20”    (508mm) 

Weight 

 

                        120 lbs. 

Enclosure   

                        18mm thick, 13 ply Baltic Birch plywood 

Mounting Methods                           Floor mount 

 

 

 

 

 

 

 

 

 

 

 

 

                

Note:  

D-CAT 

is a trademark of ISP Technologies LLC 

 

 

 

Summary of Contents for SA118

Page 1: ...1 ...

Page 2: ... into this unit This active speaker system has an internal amplifier and an externally visible heatsink located on the back of the speaker for cooling of the internal amplifier Care should be taken to avoid placing this active speaker in a location where the external heatsink does not allow proper cooling of the internal amplifier Avoid placing this system close to other heat sources The external ...

Page 3: ...nnected to one of ISP Technologies passive satellite subwoofers SP118 or SP115 The amplifier receives its input signal from an internal fourth order crossover network specifically designed to provide optimized phase and frequency response for a composite system The internal amplifier is based on ISP Technologies patent pending D CAT Dynamic Current Amplifier Technology amplifier technology The D C...

Page 4: ...t of the cabinet relative to floors and walls will affect the low frequency response Placing it closer to the floor and walls will reinforce the low frequency response Also make sure that adequate space at least 6 inches is left behind the cabinet for airflow over the internal amplifier heatsink A pole mount socket is provided on the top of the SA118 for mounting one of ISP Technologies Active Ser...

Page 5: ...hase coherent with any of the Tripower series This switch will not change the phase of any of the balanced outputs 6 INPUT SENSITIVITY This control determines the overall input level of the signal to the power amp section of the subwoofer cabinet Adjusting this level will not affect the level of the signal passing through to the full range or the high pass outputs 7 LEFT BALANCED INPUT This female...

Page 6: ...he fuse cover module after it is pulled out NOTE A SMALL COMPARTMENT IS ALSO PROVIDED WITHIN THE FUSE COVER MODULE FOR STORING A SPARE FUSE 2 After replacing the fuse with another of identical specifications push the fuse cover module fully back into place ensuring that the fuse has snapped onto the fuse holder inside the power inlet module ...

Page 7: ...7 CONNECTION DIAGRAM ...

Page 8: ...igured to AES standards Audio Engineering Society These connections are connected in a loop through configuration from the inputs to the full range outputs and will accept a balanced line level input The standard phase configuration is that pin 2 is pin 3 is and pin 1 is shielded ground on the XLR ...

Page 9: ...ormer has internal thermal fuse self resetting Transducer Low Frequency Transducer Diameter 18 381mm Voice Coil Diameter 4 76 2mm Power Handling 500 watts RMS D CAT Technology Power Amplifier Low Frequency Amplifier Power Output Stand Alone 600 watts RMS Power Output with SP118 SP115 900 watts RMS THD 0 06 typical Line Input Power Voltage 117VAC 60 Hz Current 6 9 amps Power 800 watts Physical Heig...

Page 10: ...from the speaker It is recommended that the fins have at least 6 inches of clearance from any obstruction to allow proper ventilation to occur In addition the amplifiers are thermally protected internally via a thermal switch which will attenuate the signal 40db when the temperature exceeds a certain point When the temperature drops below a certain point full signal will be restored Tests have sho...

Page 11: ...l not be responsible for any damages incurred in shipping of any unit Any claim will need to be settled with the shipping company The warranty will be voided if the serial number has been tampered with in any way Should you have any questions for the repair department prior to returning the product please call 1 248 620 6795 NOTE This Product may be covered under one or more of the following paten...

Reviews: