10
TROUBLE
POSSIBLE CAUSE
REMEDY
4. Corner of crown distorted or
fractured
1. Excessive compression
2. Broken driver end
3. Worn bender bar
4. Clincher improperly aligned
or worn
5. Incorrect wire size
"A" Page 12
"G" Page 15
"D" Page 13
"B,C" Page 12,13
"K" Page 17
5. Stitch crown not flat and legs
not bent into work
1. Insufficient compression
"A" Page 12
6. One or both legs turn out
1. Clincher improperly aligned
2. Dull cutters
7. Flat piece of wire
"L" Page 17
"M" Page 18
"L" Page 17
"L" page 17
8. Stitches come out in pieces
"L" Page 17
"L" Page 17
"M" Page 18
"K" Page 17
"D" Page 13
9. Both stitcher legs are either
too long or too short
See "Changing Work Thickness"
Page 7
"C" Page 13
"I" Page 16
1. Rotator is dirty
2. Improperly adjusted lower wire
straightener
3. Broken or worn rotator
4. Improperly aligned rotator
Face plate not adjusted properly
1. Improperly aligned rotator
2. Weak rotator operating spring
3. Improperly adjusted upper wire
straightener
4. Incorrect wire size
5. Wire jammed in bender bar
grooves
M2000 Head Trouble Shooting