20
C
CAUTION
As a precautionary measure-When remov-
ing the head from any stitching machine
make SURE that the power to the ma-
chine has been turned OFF or discon-
nected.
1. Lift end of spring
out of rotator
4. Pull rotator forward
2. Swing spring up to
disengage. Lift out
3. Slip rotator operating cam off stud.
CAUTION
The rotator operating cam can be
installed backwards. Be sure to read
and follow the instructions "F"on page
21 before reassembling.
6. Remove the two lower clips.
5. Remove the
upper face plate
clips.
7. Position grip
spring housing
between tension
pawl spring retainer
and cutter housing
8. Remove face
plate by sliding
face plate to the left
and lifting up.
10. Remove friction
plug and spring.
12. Remove rotator holder.
11. Remove grip release slide.
9. Remove the cutter
operating slide
A
DISMANTLING M2000 STITCHING HEAD
(CTTT2605 Scene 19)
(CTTT2605 Scene 20)
B