2009 iSpa Owner’s Manual
LTR20091084, Rev. A
Operating
Your Spa
18
Message
Meaning
Action Required
ICE
Potential freeze condition detected.
No action required. The pumps and the blower will auto-
matically activate regardless of spa status.
LF
Persistent low flow problems. Heater
is shut down, but other spa functions
continue to run normally. Displays on the
fifth occurrence of the HL or HFL mes
-
sage within 24 hours.
Follow action required for HL or HFL message. Heating
capacity of the spa will not reset automatically. Press any
button to reset.
OHS
Overheat protection. The spa has shut
down. One of the sensors has detected
that the spa water is 110°F.
DO NOT ENTER THE WATER. Remove the spa cover and
allow water to cool. At 107°F, the spa should automati
-
cally reset. If spa does not reset, shut off the power to
the spa and call your dealer or service organization.
OHH
Overheat protection (spa is shutdown).
One sensor has detected 118˚F (48˚C)
at the heater.
DO NOT ENTER THE WATER!
Remove the spa cover and allow spa to cool below 107˚F
(42˚C). Press any button on the topside display to reset
spa. If spa will not reset after spa has cooled, turn
off power for approximately 30 seconds and then turn
power back on. If display message is repeated then shut
the power off to the spa and call your dealer or service
organization.
Pr
When your spa is first actuated, it will go
into priming mode.
The priming mode will last for up to four minutes and
then the spa will begin to heat and maintain the water
temperature in the Standard mode.
SL
Indicates heater is in Sleep Mode.
None.
SnA
Snb
Spa is shut down. The sensor that is
plugged into the sensor “A” or “B” jack is
not working.
If the problem persists, contact your dealer or service
organization. (May appear temporarily in an overheat
situation and disappear when the heater cools.)
SnS
Sensors are out of balance.
If this is alternating with the tem-
•
perature, it may just be a temporary
condition.
If the display shows only this mes-
•
sage (periodically blinking), the spa is
shut down.
Contact your dealer or service organization.
ST
Indicates heater is in Standard Mode.
None.
Summary of Contents for PORTABLE SPA 2009
Page 1: ...LTR20091084 Rev A 9 1 09 Preliminary...
Page 11: ...Preparing for Your New Portable Spa 9...
Page 23: ...Operating Your Spa 21...
Page 46: ...2009 iSpa Owner s Manual LTR20091084 Rev A Appendix 44...
Page 47: ...Appendix 45...