2009 iSpa Owner’s Manual
LTR20091084, Rev. A
Pr
eparing f
or
Your Ne
w P
or
tab
le Spa
6
Do not use extension cords. Using an extension cord
will void your warranty.
Do not bury the power cord. If your cord becomes dam-
aged, replace it before next usage.
If you need to replace your cord, replace it with a 15
amp GFCI connection. The cord may not be longer than
15 feet (4.6 m).
Testing the GFCI
Test the GFCI plug prior to first use and periodically
when the spa is powered. To test the GFCI plug ver
-
sion, follow these instructions. (Spa should already be
plugged in and operational.)
Press the TEST button on the GFCI. The GFCI will
1.
trip and the spa will stop operating.
Press the RESET button on the GFCI. The GFCI will
2.
reset and the spa will turn back on.
The spa is now safe to use.
If the GFCI trips while the spa is in use, press the RE
-
SET button. If the GFCI does not reset, unplug the spa
and call your local dealer for service. DO NOT USE THE
SPA!
240 Volt Electrical Installa-
tion
All 240V spas must be permanently connected (hard-
wired) to the power supply. Use one 50 amp GFCI with
four #8 AWG copper wires. See the wiring diagram on
page 8.
These instructions describe the only acceptable
electrical wiring procedure . Spas wired in any
other way will void your warranty and may re-
sult in serious injury .
When installed in the United States, the electrical wir-
ing of this spa must meet the requirements of National
Electric Code, ANSI/NFPA 70-2008 and any applicable
local, state, and federal codes.
The electrical circuit must be installed by an elec-
trical contractor and approved by a local building
or electrical inspector .
Failure to comply with state and local codes may
result in fire or personal injury and will be the
sole responsibility of the spa owner .