Section 3: Glossary and Terms to Know

 

 

Add-On Kit (#ACL1): 

Filter add on kit for adding additional in line filters to an existing system. Comes 

with quick-connect elbow fittings, filter clamps, and additional tubing

 

Alkaline Remineralization Filter* (#FA15): 

6th stage. Remineralizes the RO water and neutralizes the pH 

 

Auto Flush Solenoid Valve (#ASOF7): 

Automatically flushes the RO membrane to preserve membrane life 

and efficiency 

 

Booster Pump (#PMP5): 

24 volt booster pump used by residential iSpring RO systems 

 

Check Valve (#ACV1K): 

One way valve that does not allow water back into the membrane housing. Looks 

like a standard elbow fitting and is located on the RO water port of the membrane housing 

 

CTO Carbon Block Filter (#FC15): 

3rd stage. 5 micron 10” carbon block filter. Further reduces any 

residual chlorine, tastes, and odors before the water reaches the RO membrane

 

Drain Saddle (#ADS1): 

Attaches to your under-sink drain pipe to secure the drain tube coming from the 

system

 

Drinking Faucet (#GA1-BN): 

The output source for the RO water. The faucet is a non-air gap faucet with a 

¼” tubing connection. The optimal sized counter-top hole for the faucet is ½”, but holes up to approximately 
1 ½” will work

 

Elbow Fittings (#4044K): 

Quick connect elbow fittings used on the system (except for on the membrane 

housing and cap). ¼” tubing connection and ¼” NPT male thread

 

Elbow Fittings on Membrane Housing (#4042K): 

Quick connect elbow fittings used on the membrane cap 

and drain port of the membrane housing. ¼” tubing connection and ⅛” NPTF male thread

 

Feed Water Adapter (#AFW43): 

Goes in line with your cold water line and branches off a water supply 

line to the RO system. Can adapt to ⅜” and ½” cold water lines 

 

Feed Water Solenoid Valve (#ASOW7): 

Opens the water supply to the booster pump when the low 

pressure switch and high pressure switch are both on. Shuts off the water supply when one or both turn off

 

Flow Restrictor (#AFR300): 

Limits the drain water flow, keeping pressure in the system and allowing the 

RO process to occur

 

Flow Sensor Switch* (#FSS): 

Detects water flow to turn the UV filter on and off as needed

 

GAC Filter (#FG15): 

2nd stage. 5 micron 10” granulated activated carbon filter. Reduces chlorine, tastes, 

and odors from the water

 

GPD: 

Gallons Per Day

 

High Pressure Switch (#ALP1):

 Receives pressure signals from the pressurized storage tank. Turns on 

when the tank pressure is below 20 PSI and turns off when tank pressure reaches 35 PSI (e.g. tank full)

 

Housing Wrench for Membrane Housing (#AWR1): 

Housing wrench used to screw on and unscrew the 

membrane housing cap 

 

Housing Wrench for Stages 1, 2, and 3 (#AWR2): 

Housing wrench used to screw on and unscrew the 

stage 1, 2, and 3 filter housings  

 

Ice Maker Kit (#ICEK): 

Add on kit that allows you to run water from the system to your fridge ice maker 

or fridge water dispenser

 

Leak Stopper (#ALS1): 

Protects from any possible leaks by cutting off the water supply when the sponge 

absorbs water

 

Low Pressure Switch (#ALP1): 

Turns on when the source water pressure reaches 7 PSI, turns off when 

source water pressure drops below 7 PSI

 

Membrane Housing and Cap (#NW12): 

Horizontal housing that the RO membrane is inserted into

 

Membrane Housing O-Ring (#ORM): 

2 ½” O.D. O-ring used to create the seal between the membrane 

housing and the membrane cap

 

Post Carbon Filter (#FT15): 

5th stage. Works as a final polishing filter before the water is delivered to the 

faucet

 

Summary of Contents for RCC1P

Page 1: ...iSpring Reverse Osmosis Water Filtration Systems INSTALLATION INSTRUCTIONS OWNER S MANUAL Ver 02 2020 Copyright 2005 2020 ISPRING WATER SYSTEMS LLC All rights reserved...

Page 2: ...m has certified by WQA to NSF ANSI Standard 58 for the reduction of TDS as verified and substantiated by test data Please review the attached iSpring RO System WQA Gold Seal Certification or the WQA w...

Page 3: ...alling the RO Faucet 9 Step 3 Installing the Drain Saddle 9 Step 4 Installing the Vertical Filters Stages 1 2 and 3 10 Step 5 Installing theTank Shut Off Valve 10 Step 6 Installing the Reverse Osmosis...

Page 4: ...r pressure 70 PSI otherwise a pressure regulator part no APR70 is required to lower the PSI to the maximum level Operating water temperature range 40 100 F 4 37 C This RO system is NOT designed for HO...

Page 5: ...in moisture 3 Pre Filter Housings and Cartridges Storage Tank RO faucet with installation kit Feed Water Adapter AFW43 4 Color Tubing Set Drain Saddle Tank Valve Housing Wrenches Plumbers Tape Spare O...

Page 6: ...ort and waste water port The RO water is forced through the 0001 micron sized holes of the RO membrane and exits through the one way Check Valve on the membrane s pure water exit port The water reject...

Page 7: ...k sleeve pops out of the fitting when doing this simply pop it back in 4 Insert the tube into the fitting until you reach the mark on the tube You will feel resistance when the tube reaches the small...

Page 8: ...in your sink or counter top 1 It s highly recommended to watch the YouTube video How To Drill Faucet Holes to get a better understanding of the process Depending on what kind of countertop you have yo...

Page 9: ...e pure water line and the flow restrictor doubles as one way valve preventing drain water from entering back into the system Installation Steps Before you begin the installation it is highly recommend...

Page 10: ...ular OFF position Turn on the CWSV slowly and ensure you are getting a proper seal 1 4 Connect the 1 4 RED tubing to the AFW43 Feed Water Adapter with Bushing to convert 3 8 COMP to NPT Step 2 Install...

Page 11: ...ound the hole 3 3 Cut the BLACK tubing end to make a 45 degree angle Slip the plastic nut and front plate on the tubing Insert the tubing into the 1 4 hole in the drain pipe install the back plate and...

Page 12: ...go in a certain direction Make sure the end with the rubber washer faces up thereby attaching it to the housing cap Step 5 Installing Tank Shut Off Valve TSV 5 1 Wrap 10 15 wraps of Teflon tape clock...

Page 13: ...and 9 This is very important to avoid leaking and damage to the O ring 6 6 Place the membrane housing cap back on and hand tighten it then use the housing wrench to tighten it another of a turn Do no...

Page 14: ...efer to How to Use the Compression Fitting 7 7 You may neatly organize the tubing but make sure to leave enough length so the filter system can be moved freely in and out of the cabinet when replacing...

Page 15: ...RO faucet to let it begin filling again 8 8 If your system has a UV filter plug in the UV power and check to make sure the UV light is turning on when water flows through it The UV filter has a Flow...

Page 16: ...epot com This reverse osmosis system contains a replaceable component critical to the efficiency of the system Replacement of the reverse osmosis component should be with one of identical specificatio...

Page 17: ...lter housing off without removing the system from the wall Otherwise you will need to pull the system out lay it down and remove the housings at that point Be careful with the tubing connections when...

Page 18: ...ring is properly seated on the end of the membrane housing as shown in the previous images We recommend replacing the O ring every 3 years to prevent leaking due to an expired or dried out O ring 8 P...

Page 19: ...Kit ICEK The Ice Maker Kit model iSpring ICEK can be purchased separately to feed RO water to your refrigerator for crystal clear ice cubes and great tasting water If you choose to hook up the system...

Page 20: ...herefore not allowing water to pass through See Pump does not start b Incorrect installation Verify all tubing connections c Tank valve is closed Make sure the tank valve is in line with the yellow tu...

Page 21: ...tinuous drain a Keep in mind that it will take anywhere from 1 3 hours for the system to fill the tank from empty and the drain line will be trickling during this time If the drain line continues to r...

Page 22: ...in line with your cold water line and branches off a water supply line to the RO system Can adapt to and cold water lines Feed Water Solenoid Valve ASOW7 Opens the water supply to the booster pump wh...

Page 23: ...ir respective caps Stage 1 See Through Sediment Filter Housing HC12 Transparent stage 1 housing that holds the sediment filter The see through housing allows for the sediment filter to be visually ins...

Page 24: ...nation of the proper equipment necessary to meet your requirements and we do not authorize others to assume such obligation on our behalf This Limited Warranty does not cover any Manufacturer supplied...

Page 25: ...ufacturer warranty and lifetime tech support for all of our products However we do not have the order information from websites other than 123Filter com Amazon Home Depot etc so please be sure to fill...

Page 26: ......