PPM: 

Parts Per Million, a unit used to measure TDS readings

 

Pressurized Holding Tank (#T32M): 

3.2g capacity pressurized water holding tank. The air bladder forces 

the water to the drinking faucet when the faucet is opened. Tank comes pre-pressurized and should read 7-10 
PSI when empty

 

PSI: 

Pounds Per Square Inch, a unit used to measure water pressure

 

Quick Connect Fitting: 

A secure, easy to connect and disconnect type of fitting used on the system. The 

tubing is inserted past the tiny O-ring located inside each fitting, then locked into place by the spider lock 
and blue clip

 

Reverse Osmosis (RO) Membrane (#MC7): 

4th stage. High rejection, 0.0001 micron, thin-film composite 

(TFC) reverse osmosis membrane, the heart of the reverse osmosis process

 

Sediment Filter (#FP15): 

1st stage. 5 micron 10" polypropylene sediment filter. Traps particulate matter 

such as dirt, rust, and silt 

 

Stage 1, 2, and 3 housing O-Rings (#ORF): 

3 ⅝” O.D. O-ring used to create the seal between the stage 1, 

2, and 3 filter housings and their respective caps 

 

Stage 1 See-Through Sediment Filter Housing (#HC12): 

Transparent stage 1 housing that holds the 

sediment filter. The see through housing allows for the sediment filter to be visually inspected

 

Stage 2 GAC Filter Housing (#HW12): 

Solid white housing that holds the stage 2 GAC filter

 

Stage 3 CTO Filter Housing (#HW12): 

Solid white housing that holds the stage 3 CTO filter

 

T Fitting on Stage 5 Post Carbon Filter (#7544K): 

T fitting located on the right side of the stage 5 Post 

Carbon Filter

 

Tank Valve (#ABV2K): 

On/off valve that screws onto the top of the tank

 

TDS: 

Total Dissolved Solids, a measure of the contamination level of a water source

 

TDS Meter (#TDS3): 

Handheld meter used to measure water quality

 

Transformer for Booster Pump (#ATRF5): 

Power supply used for the PMP5 booster pump on residential 

iSpring RO systems

 

Tubing (#T14B / #T14W): 

¼” food grade tubing used on the system

 

UV Replacement Bulb* (#UVB11): 

Replacement bulb for the UV filter

 

UV Transformer/Ballast* (#UVT11A/UVT11B):

 Power supply for the UV filter. Indicator lights on the 

ballast will only light up when water is flowing. UVF11A is for 110V power sources, UVF11B is for 220V 
power sources  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
*Alkaline filter claims DI filter claims, and UV filter claims not evaluated and not certified by WQA. 
 
 

Summary of Contents for RCC1P

Page 1: ...iSpring Reverse Osmosis Water Filtration Systems INSTALLATION INSTRUCTIONS OWNER S MANUAL Ver 02 2020 Copyright 2005 2020 ISPRING WATER SYSTEMS LLC All rights reserved...

Page 2: ...m has certified by WQA to NSF ANSI Standard 58 for the reduction of TDS as verified and substantiated by test data Please review the attached iSpring RO System WQA Gold Seal Certification or the WQA w...

Page 3: ...alling the RO Faucet 9 Step 3 Installing the Drain Saddle 9 Step 4 Installing the Vertical Filters Stages 1 2 and 3 10 Step 5 Installing theTank Shut Off Valve 10 Step 6 Installing the Reverse Osmosis...

Page 4: ...r pressure 70 PSI otherwise a pressure regulator part no APR70 is required to lower the PSI to the maximum level Operating water temperature range 40 100 F 4 37 C This RO system is NOT designed for HO...

Page 5: ...in moisture 3 Pre Filter Housings and Cartridges Storage Tank RO faucet with installation kit Feed Water Adapter AFW43 4 Color Tubing Set Drain Saddle Tank Valve Housing Wrenches Plumbers Tape Spare O...

Page 6: ...ort and waste water port The RO water is forced through the 0001 micron sized holes of the RO membrane and exits through the one way Check Valve on the membrane s pure water exit port The water reject...

Page 7: ...k sleeve pops out of the fitting when doing this simply pop it back in 4 Insert the tube into the fitting until you reach the mark on the tube You will feel resistance when the tube reaches the small...

Page 8: ...in your sink or counter top 1 It s highly recommended to watch the YouTube video How To Drill Faucet Holes to get a better understanding of the process Depending on what kind of countertop you have yo...

Page 9: ...e pure water line and the flow restrictor doubles as one way valve preventing drain water from entering back into the system Installation Steps Before you begin the installation it is highly recommend...

Page 10: ...ular OFF position Turn on the CWSV slowly and ensure you are getting a proper seal 1 4 Connect the 1 4 RED tubing to the AFW43 Feed Water Adapter with Bushing to convert 3 8 COMP to NPT Step 2 Install...

Page 11: ...ound the hole 3 3 Cut the BLACK tubing end to make a 45 degree angle Slip the plastic nut and front plate on the tubing Insert the tubing into the 1 4 hole in the drain pipe install the back plate and...

Page 12: ...go in a certain direction Make sure the end with the rubber washer faces up thereby attaching it to the housing cap Step 5 Installing Tank Shut Off Valve TSV 5 1 Wrap 10 15 wraps of Teflon tape clock...

Page 13: ...and 9 This is very important to avoid leaking and damage to the O ring 6 6 Place the membrane housing cap back on and hand tighten it then use the housing wrench to tighten it another of a turn Do no...

Page 14: ...efer to How to Use the Compression Fitting 7 7 You may neatly organize the tubing but make sure to leave enough length so the filter system can be moved freely in and out of the cabinet when replacing...

Page 15: ...RO faucet to let it begin filling again 8 8 If your system has a UV filter plug in the UV power and check to make sure the UV light is turning on when water flows through it The UV filter has a Flow...

Page 16: ...epot com This reverse osmosis system contains a replaceable component critical to the efficiency of the system Replacement of the reverse osmosis component should be with one of identical specificatio...

Page 17: ...lter housing off without removing the system from the wall Otherwise you will need to pull the system out lay it down and remove the housings at that point Be careful with the tubing connections when...

Page 18: ...ring is properly seated on the end of the membrane housing as shown in the previous images We recommend replacing the O ring every 3 years to prevent leaking due to an expired or dried out O ring 8 P...

Page 19: ...Kit ICEK The Ice Maker Kit model iSpring ICEK can be purchased separately to feed RO water to your refrigerator for crystal clear ice cubes and great tasting water If you choose to hook up the system...

Page 20: ...herefore not allowing water to pass through See Pump does not start b Incorrect installation Verify all tubing connections c Tank valve is closed Make sure the tank valve is in line with the yellow tu...

Page 21: ...tinuous drain a Keep in mind that it will take anywhere from 1 3 hours for the system to fill the tank from empty and the drain line will be trickling during this time If the drain line continues to r...

Page 22: ...in line with your cold water line and branches off a water supply line to the RO system Can adapt to and cold water lines Feed Water Solenoid Valve ASOW7 Opens the water supply to the booster pump wh...

Page 23: ...ir respective caps Stage 1 See Through Sediment Filter Housing HC12 Transparent stage 1 housing that holds the sediment filter The see through housing allows for the sediment filter to be visually ins...

Page 24: ...nation of the proper equipment necessary to meet your requirements and we do not authorize others to assume such obligation on our behalf This Limited Warranty does not cover any Manufacturer supplied...

Page 25: ...ufacturer warranty and lifetime tech support for all of our products However we do not have the order information from websites other than 123Filter com Amazon Home Depot etc so please be sure to fill...

Page 26: ......

Page 27: ...3020 Trotters Parkway Alpharetta GA 30004 USA 123Filter com For questions comments or technical support please contact us at support 123filter com 678 261 7611 Monday Friday 8 30 a m 5 30 p m EST...

Reviews: