v.
Rotate the Water Hardness Adjustment Nut in a clockwise direction. The bigger the rotation angle,
the higher the water hardness.
(2)
Precautions Before Commissioning
•
Verify the water inlet pipe and sewage pipe are connected as required. All piping connections
must comply with relevant national standards.
•
Attach the sewage and overflow hoses onto the sewer pipe, but do not insert them directly into
the sewer pipe. A gap of 100 mm shall be maintained with the bottom of the sewer pipe.
•
Verify the water source pressure is within the range of 20psi - 50psi.
(3)
Notes
•
The acceptable water pressure range is 20~50 psi. If the pressure is higher or lower than this, it
is recommended to install a pressure stabilizer.
•
The operating ambient temperature requirement is 33.8°F ~102.2°F. If the temperature is higher
or lower than this, heat preservation measures should be executed.
•
Do not remove the clips when the system is in operation; relieve the pressure before removing
the clips.
•
This product should be installed out of reach of children.
(4)
Equipment Installation
Step 1.
Confirm proper installation conditions, then unpack the equipment and verify that all
accessories are present. Prepare the installation tools and confirm that the water inlet and outlet
pipes, power supplies, sewage pipes, and floor drains at the installation site meet the appropriate
requirements.
Step 2.
Close the indoor water inlet valve
completely, then
open any faucets
in the room to remove
the remaining water in the indoor water pipes.
Step 3.
Use a screwdriver to unscrew the two screws on the back of the machine. At this time, you can
lift the black lid, unplug the cable on the control panel, and remove the entire lid.
Step 4.
Add salt to brine tank. Add sufficient softening salt to the brine tank, or about 2/3 of the brine
tank volume.
Step 5.
Remove two one-inch connectors, two O-rings, and a grease pack from the accessory package.
Put the O-ring into the one-inch connector, tear off the grease package, squeeze out the grease,
being sure to apply it to the O-ring evenly. Wipe your hands afterward to maintain cleanliness.
Step 6.
Connect two one-inch quick-connectors, pull out the clamps, insert the quick-connectors into
the water inlet and outlet, and re-insert the clamp.
Step 7.
Connect the water inlet and outlet pipes. Pay attention to the direction of the water inlet and
outlet and prevent the connection pipes from bearing extra stress.
Step 8.
Take the sewage pipe(the original sewage pipe is 8.6ft. long) and cut into two pieces, one for
sewage and one for overflow.Each section should be about 4.3 ft. long.