(5)
Press and hold "MENU" and "SET/REGEN" at the same time for 3 seconds to enter the
following user menu settings:
SYSTEM LANGUAGE:
Choose the system language.
UNITS:
Choose the system’s unit of measurement: metric or gallons.
EFFICIENCY & CAPACITY SETTINGS:
There are 3 settings to choose from: High Efficiency,Standard
Capacity, and Iron & Manganese.The values for these settings
are set in the Factory Options and are used to calculate the
system capacity and refill time.
REFILL:
This value should match the BLFC flow washer. It is used to
calculate the refill time.
BRINE MAKE TIME:
This value is the time allowed for the salt to dissolve in the water
to create the brine solution. It is the amount of time ahead of the
scheduled regeneration time that the water will be added to “top
off” the brine already prepared in the brine tank.
BRINE PRE-FILL%:
This is the percentage of water that will be added to the brine
tank after a regeneration. The default is 70%. The remaining
water will be added just prior to the regeneration and will be
proportional to the amount of capacity left in the system.
DAILY RESERVE:
This value is used to calculate the reserve capacity. Reserve
Capacity = # of People x DAILY RESERVE. The 4-day option is
used to calculate the daily water consumption for 28 days, and
the average daily water consumption for each day of the week is
calculated separately.
BW.(RINSE) OVERRIDE:
This setting can be used to skip the backwash (rinse) cycle. As
an example, if the setting is 10, the system will skip 10
backwash (rinse) cycles. The setting will only work if the
WATER SOURCE is set to MUNICPAL for clean water
applications.
FORCED REGEN:
When set to ON, the system will start a forcedregeneration
when the remaining capacity reaches 3% and when no water is
used for 10 minutes. The regeneration consists of 20 minutes of
Brine and 10 minutes of Rinse. The 30 minute regeneration
willrestore up to 33% of the system capacity. At the next
regeneration time (2:00 a.m.), the system will automatically
perform a standard regeneration to restore capacity to 100%.
SMART CLEAN:
When set to ON, the system will perform a 10 minute
(adjustable) backwash and rinse if there is no water flow
detected after 7 days (adjustable). The regeneration will occur
at the scheduled REGEN TIME.