(5)

 

Press and hold "MENU" and "SET/REGEN" at the same time for 3 seconds to enter the 
following user menu settings: 
 

 

SYSTEM LANGUAGE: 

Choose the system language. 

UNITS: 

Choose the system’s unit of measurement: metric or gallons. 

EFFICIENCY & CAPACITY SETTINGS: 

There are 3 settings to choose  from:  High Efficiency,Standard 
Capacity, and Iron & Manganese.The values for these settings 
are set in the Factory Options and are used to calculate the 
system capacity and refill time. 

REFILL: 

This value should match the BLFC flow washer. It is used to 
calculate the refill time. 

BRINE MAKE TIME: 

This value is the time allowed for the salt to dissolve in the water 
to create the brine solution. It is the amount of time ahead of the 
scheduled regeneration time that the water will be added to “top 
off” the brine already prepared in the brine tank. 

BRINE PRE-FILL%: 

This is the percentage of water that will be added to the brine 
tank after a regeneration. The default is 70%. The remaining 
water will be added just prior to the regeneration and will be 
proportional to the amount of capacity left in the system. 

DAILY RESERVE: 

This value is used to calculate the reserve capacity. Reserve 
Capacity = # of People x DAILY RESERVE. The 4-day option is 
used to calculate the daily water consumption for 28 days, and 
the average daily water consumption for each day of the week is 
calculated separately. 

BW.(RINSE) OVERRIDE: 

This setting can be used to skip the backwash (rinse) cycle. As 
an example,  if the setting is 10, the system will skip 10 
backwash (rinse) cycles. The setting will only work if the 
WATER SOURCE is set to MUNICPAL for clean water 
applications. 

FORCED REGEN: 

When set to ON, the system will start a forcedregeneration 
when the remaining capacity reaches 3% and when no water is 
used for 10 minutes. The regeneration consists of 20 minutes of 
Brine and 10 minutes of Rinse. The 30 minute regeneration 
willrestore up to 33% of the system capacity. At the next 
regeneration time (2:00 a.m.), the system will automatically 
perform a standard regeneration to restore capacity to 100%. 

SMART CLEAN: 

When set to ON, the system will perform a 10 minute 
(adjustable)  backwash and rinse if there is no water flow 
detected after 7 days  (adjustable). The regeneration will occur 
at the scheduled REGEN TIME. 

www.123filter.com

   |   (678) 261-7611   |   

support@123filter.com 

Page 18 

Summary of Contents for WCS45KG

Page 1: ...WCS45KG Whole House Central Softener INSTALLATION INSTRUCTIONS OPERATING MANUAL Ver 02 2021 Copyright 2005 2021 ISPRING WATER SYSTEMS LLC All rights reserved...

Page 2: ......

Page 3: ...r in everyday life and deliver pure healthy and tasty water to you and your family At iSpring we strive to develop products to the highest of standards and aim to make excellent drinking water accessi...

Page 4: ......

Page 5: ...4 Product Operation Specifications 5 Before You Start 6 Material Details 7 Installation InstallationRequirements 9 InstallationInstructions 11 Using the System Programming the Central Softener System...

Page 6: ...ter purifier may result in malfunction damage and possible injury to the enclosure or water supply line In case of malfunction due to damage or failure of the power supply system unplug the system imm...

Page 7: ...Dimensions TOP VIEW SIDEVIEW FRONTVIEW Note all dimensions are in millimeters unless otherwise specified www 123filter com 678 261 7611 support 123filter com Page 4...

Page 8: ...C120V 60Hz Output AC12V 650mA Pressure Tank Thread 2 5 NPSM Inlet Outlet Connector 1 NPT Rated Service Flow Rate 8 GPM 30 L min Peak Flow Rate 26 GPM Capacity 45000 grain Independent 3rd party laborat...

Page 9: ...hock Note Product installation and use must strictly comply with the requirements of this manual Do not perform any operation on the product without first reading and understanding the contents of thi...

Page 10: ...x 1 pcs sewage and overflow pipe a translucent pipe 1 pcs stainless steel clamps in the PE bag 2 pcs hex key in the PE bag 1 pcs connect screws NPT1M in the PE bag 2 pcs O rings in the PE bag 2 pcs gr...

Page 11: ...3 Inlet Outlet Connections Types 4 Bypass Assembly www 123filter com 678 261 7611 support 123filter com Page 8...

Page 12: ...se Ensure there is proper space around the device and do not apply any external force to the device or its connecting pipes Do not install this product near corrosive substances or gases which may lea...

Page 13: ...tallation When connecting screw parts seal rings are generally installed Please be aware that excessive force may cause the threads to slip and the screw to crack Connect the hose to the brine suction...

Page 14: ...ass ii Mount the meter sensor into the meter sensor mounting hole This device handles meter and control functions after connecting to the appropriate controller iii In case of equipment failure or oth...

Page 15: ...the water inlet and outlet pipes power supplies sewage pipes and floor drains at the installation site meet the appropriate requirements Step 2 Close the indoor water inlet valve completely then open...

Page 16: ...olly discharged the exhaust sound disappears and water steadily flows out of the sewage pipe completely open the water inlet valve and flush the resin tank until the water is completely clean The flus...

Page 17: ...he first time run water from the faucet for 5 minutes After this the softened water can be used normally Step 21 Open a cold water tap nearby and let the water run Then close the tap Verify the water...

Page 18: ...u display immediately SET REGEN While in the unlocked state press and hold for 3 seconds to enter the manual regeneration mode You can choose vacation mode immediate regeneration or full cycle immedia...

Page 19: ...same time for 3 seconds in the unlocked state to enter the user menu settings such as language units smart clean etc b During the menu setting process if there is no activity within 1 minute the syste...

Page 20: ...ty and IRON MN These settings will determine the salt dosage and capacity for the system WATER SOURCE This setting will determine if the BACKWASH OVERRIDE function will be on or off Select MUNICIPAL i...

Page 21: ...pacity left in the system DAILY RESERVE This value is used to calculate the reserve capacity Reserve Capacity of People x DAILY RESERVE The 4 day option is used to calculate the daily water consumptio...

Page 22: ...nit size and salt setting The settings are optimized to maximize salt and water use efficiency The settings can be manually adjusted Users can adjust these parameters at any time with the help of an a...

Page 23: ...f the regeneration process Cycle function programming Service After the source water flows through the water softener at an absolute pressure and flow rate the Na in the ion exchange resin exchanges w...

Page 24: ...your requirements Display Format Metric or US formats are available Multi Language Function English Spanish French and other languages are available Intelligent calculation The system can calculate th...

Page 25: ...r that can be treated during the system regeneration cycle the number of users the amount of reserved water the time to the next regeneration the time to the last regeneration the total number of rege...

Page 26: ...y of the water softener in actual use is not only related to the quality of the raw water but also associated with the softener s water flow rate When in use the flow rate should be appropriately low...

Page 27: ...When the water supply in a residential area is shut down the main water main valve should be closed immediately The municipal water supply may cause negative pressure to the household pipeline and dam...

Page 28: ...let water pressure is too low Increase the inlet water pressure which should be greater than 20 psi Brine pipeline leak Check all components of the brine suction pipe and eliminate the leakage point N...

Page 29: ...the gasket Brine tank overflow Replenishment time is exceedingly high Reset the replenishment time The machine is leaking Turn off the machine and contact iSpring Need help with troubleshooting If yo...

Page 30: ...e Depot etc so please be sure to fill in that information upon registration of your system If you have any questions or concerns about your product please do not hesitate to call or email us or put it...

Page 31: ......

Page 32: ...Atlanta GA USA iSpringFilter com For questions comments or technical support contact us at support 123Filter com 678 261 7611 Monday Friday 8 30 a m 5 30 p m EST...

Reviews: