DC/DCM100 to 330 Dust Collector - Instruction Manual & Parts

GENERAL SAFETY RULES

 

PERSONAL SAFETY

USE AND EqUIPMENT MAINTENANCE

  

KeeP WORK AReA cleAn.

• 

 

KeeP cHIlDRen AWAY.  

Do not let visitors come in contact with the equipment.  All visitors should    

be kept away from the work area.

 

GUARD AGAInST elecTRIc SHOcK.

  Non-skid footwear is recommended where damp or wet ground 

may be encountered. A ground fault circuit interrupter protected power line must be used for these 

conditions.

 

DReSS PROPeRlY.

 Do not wear loose clothing or jewelry. They can be caught in the moving parts. Wear 

protective hair covering to contain long hair.

 

USe SAFeTY eQUIPMenT.  WeAR SAFeTY GOGGleS

 or glasses with side shields. 

 

WeAR A DUST PROOF MASK. 

 

STAY AleRT. USe YOUR cOMMOn SenSe

. Concentrate on what you are doing. Do not operate the unit 

when you are tired or under the influence of drugs or alcohol.

 

DO nOT OVeRReAcH

. Keep proper footing and balance at all times.

 

beFORe cOnnecTInG THe UnIT to an electric current, make sure that the current is the same as

that indicated on the identification plate of the collector. An electric current higher than indicated

  that could seriously injure the user and also damage the collector. If you have any doubts, do not

  connect the unit.

 

DO nOT FORce THe eQUIPMenT. It will perform better and more safely if it performs his duties

 

the way it was designed.

 

USe OF AnY OTHeR AcceSSORIeS not specified in this manual may be dangerous.

 

DIScOnnecT THe UnIT on its maintenance.

 

DO nOT AlTeR OR IMPROPeRlY USe THe UnIT. These units are precision equipment. Alteration 

unspecified or modification can lead to a dangerous situation. Only a qualified technician should 

make all repairs (•), whether electrical or mechanical. Contact your nearest repair ISTblast service. 

Use only ISTblast original parts, the use of other parts carries a risk.

WARnInG

« READ ALL INSTRUCTIONS » Failure to follow the SAFETY RULES identified by a BULLET (

) symbol listed  

BELOW and other safety precautions may result in serious personal injury. 
 

« SAVe THeSe InSTRUcTIOnS »

Summary of Contents for ISTblast DC 100

Page 1: ...ence in surface treatment www istsurface com Instruction manual 2019 01 17 DUST COLLECTOR SERIE DC DCM 100 to 330 Warranty Safety Operation Service Parts Accessory Information Registration Form Shown...

Page 2: ...ce 5 GENERAL SAFETY RULES PERSONALSAFETY UNIT USE AND 5 PERSONAL SAFETY 5 muffler optional 6 INSTALLATION 6 INSTALLATION 7 INSTALLATION con D 8 MAINTENANCE 8 MAINTENANCE con D 9 SCHEMATIC OF DC DCM MO...

Page 3: ...possibility of transport damage to the equipment inside 2 Carefully remove your ISTblast dust collector from the shipping carton and skid 3 Check your equipment immediately to ensure that it is free...

Page 4: ...ses determined solely by the user No representations are intended or made as to the suitability or engineering balance of the combination of products determined by the user in his selection nor as to...

Page 5: ...eep proper footing and balance at all times BEFORE CONNECTING THE UNIT to an electric current make sure that the current is the same as that indicated on the identification plate of the collector An e...

Page 6: ...the dust barrel option make sure the barrel is placed under the dust collector and securely connected to it 4 For electric motors operating on 3 phases ensure the rotation will be the same as that ind...

Page 7: ...g drum option make sure that the drum is properly located under the dust collector and that it has been correctly secured to it 5 Sound silencer muffler optional is to be installed directly to the air...

Page 8: ...you should not shake the dust collector s bags This will allow the dust to create a thin layer on the inside of the bag increasing the filtering efficiency It also explains why new bags may leak for...

Page 9: ...e trap to collect the dust picture 3 If you are equipped with the dust drum option simply open the lid with the ring s lever picture 4 and empty dust 3 Never wash dust bags If you have to clean them u...

Page 10: ...The reference in surface treatment www istsurface com 10 DC DCM100 to 330 Dust Collector Instruction Manual Parts SCHEMATIC OF DC DCM MODEL Back side Front side 2 6 7 9 1 9B 9A 3 8 4 5 5A...

Page 11: ...The reference in surface treatment www istsurface com 11 DC DCM100 to 330 Dust Collector Instruction Manual Parts SCHEMATIC OF INTERIOR OF DCM DC 10 13 16 17 19 15 18 11 12 14...

Page 12: ...ence in surface treatment www istsurface com 12 DC DCM100 to 330 Dust Collector Instruction Manual Parts SCHEMATIC OF ELECTRIC BOX AND INTERIOR OF DC DCM Non standard voltage is available 20 23 21 22...

Page 13: ...24 618306 1 2 x 1 2 self adhesive rubber foam 25 610287 Complete door handle 26 610223 Door latch 27 606112 1 8 urethane hose SPARE PARTS FOR DC 100 DCM 100 STOCK DESCRIPTION All sold per foot or per...

Page 14: ...oot 7 610280 8 adjustable air inlet 8 618318 x self adhesive rubber foam 9 Ascabinet Dust conveying hose sold per foot in accordance with cabinet 9A Ascabinet Clamp 9B 601427 600 V Automatic shacker D...

Page 15: ...truction Manual Parts electrical shacker optional installation 4160 Industriel Blvd Laval QC H7L 6H1 CANADA T l 1 877 629 8202 450 963 4400 Fax 450 963 5122 Stock Description 1 917850 timers 2 324560...

Page 16: ...l purchaser transportation prepaid If the inspection of the equipment does not disclose any defect in material or workmanship repairs will be made at a reasonable charge which charges may include the...

Reviews: