background image

Earth

Safe

 

40 Ah  

20   Ah 

14,2 ~ 17

24,6 ~ 28

24V/650W

 

MODEL

 

12V/650W 

Warn

ing

:

Description:

The charge controller is intended only 
for charging a battery.

Characteristics :

It is reliable and has a long life.

Short circuit protection.

The charge controller has a brake protection with full battery and has

Charge control and diversion control:

Light ions:

Never connect the charge controller to an 

inverter, as this can cause a fire hazard and is 

dangerous.

Nominal Output Power 

        

 

500W 

        

  500W 

Input Voltage Range

 

Batter

y

 

12V  

24V  

Max. Input wind power

 

500W 

500W 

 

Wind turbine Max. Input

 current

Max. Input solar Pv.

 

150W 

150W 

Recommended battery

 

12V / 150 Ah

 

24V / 150  Ah

Ownconsumption

 

≤0.2   A 

≤0.2   A 

Weight 

550   gr  

550   gr  

Size

200 x 115 x 60

  200 x 115 x 60

 

                                                Charge Controller i/HCC 650 

 

Orange

 Light Emitting Diode

When this is on, it says that the 

charge controller is charging (the charge controller is in charge

 mode).

R

ed Led

If the red light is on, it means that the charge 

controller is braking the wind generator. e.g. when the battery 

is full or when the wind speed is too high

 

 

Step 1

:

 

Connect the charge controller as it is shown on the battery.

Use  a  cable  connection  of  least  4  mm²  to  connect  the 
charge controller and the battery.

Please be sure to connect the same poles, ie negative to 
negative and positive to positive.

 

Step 1

:

 

Connect the 3 cables from the wind generator and in the 
picture above. The order is unimportant.

You can use this charger for all 3-phase wind 

generators or hydropower plants as well as 

standard solar systems. Once the battery is fully 

charged, the charge controller automatically 

brakes.

This charge controller converts AC to DC. It is a 

cost effective solution for renewable energy 

systems.

This charge controller is suitable for 500W wind 

generators and at the same time for 150W solar 

systems.

The design ensures e ffi cient ventilation and 

efficient operation suitable for AC and wind 

generators.

  

Translation of the original instructions iSTA wind turbine system 

2

4

.0

7

.201

8

I00

   

11 of 28 

Summary of Contents for i-300

Page 1: ...SAVE SAVE ENERGY PLANET TRANSLATION OF THE ORIGINAL INSTRUCTIONS Keep handy at the place of use Wind turbine system i 300 i 500 L 500 Air Speed...

Page 2: ...anslation of the original instructions 4 2 2 1 Other symbols used 5 2 2 2 Information 5 2 3 Name and address of the manufacturer and his authorised representative 5 2 4 Warranty and liability 6 2 5 Pr...

Page 3: ...3 of 28 7 6 Erecting the wind turbine 17 8 Normal Operation 18 8 2 Restart after an emergency 18 9 Shutting down the Wind Turbine System 18 10 Maintenance 19 10 1 Safety precautions during maintenanc...

Page 4: ...turbine system 2 2 Conventions used in this translation of the original instructions Safety information is always identified by a signal word and in some cases also by a hazard specific symbol DANGER...

Page 5: ...dicates general information and recommendations 2 3 Name and address of the manufacturer and his authorised representative Name ALTINEL ENERJI DIS TIC ELEK ELEKTRONIK SAN VE TIC LTD STI Phone 0090 212...

Page 6: ...the limits of use described above are considered to be contrary to the intended purpose The manufacturer is not liable for any damage resulting from such use No liability will be accepted by the manuf...

Page 7: ...ind energy into electrical energy 2 Switch switch AC Emergency Stop Button optional optional Type i HCC 800 Generates electrical voltage 12 24 48 VDC The iSTA Breeze charge controller has 40 A fuse pr...

Page 8: ...1 Nose Cover 1 2 Rotor blade 3 3 Hub for holding the blades 1 4 Generator for producing electricity 1 5 Body trage Element 1 6 Tail vane for turning the blades into the wind 1 Note For proper operati...

Page 9: ...i 500 L 500 Air Speed 12V 24V 22A 11A 12V 24V 24V 48V 35A 18A 35A 18A 35A 18A free Weight kg 5 9 6 1 6 6 7 8 Max power Housing material Plastic Plastic Aluminium Aluminium Plastic Hub flange Plastic...

Page 10: ...aking system in three steps to avoid immediate blockage of the turbine Increasing the lifetime of the stator Protection against overcharging overdischarge short circuit overload and against incorrect...

Page 11: ...d If the red light is on it means that the charge controller is braking the wind generator e g when the battery is full or when the wind speed is too high Step 1 Connect the charge controller as it is...

Page 12: ...ns All work on the wind turbine system must be carried out by authorised persons Such persons must be familiar with the safety devices and regulations prior to carrying out the work Authorised persons...

Page 13: ...sufficient height refer to Fig 3 Obstacles are defined as houses hedges trees hills etc When choosing the place of use make sure adequate room is available to tilt the tower and blades if necessary H...

Page 14: ...size and structure of the foundation depend on the soil characteristics Recommendation Ask a qualified structural engineer for advice regarding the optimal design of the foundation Fig 5 Suitable guyi...

Page 15: ...bly at windy sites Choose an assembly site which is sheltered from the wind The assembly process requires calm weather conditions Fig 6 Assembling the wind turbine Repellerblatt 1 mit flacher Seite an...

Page 16: ...110 Cable cross section mm 2 5 4 6 10 16 25 Distance between generator and charge controller m 11 11 18 18 29 20 44 44 70 68 113 Cable cross section mm 2 5 4 6 10 16 25 Move rotor to Y position see Fi...

Page 17: ...efer to Fig 5 Remove the short circuit Fig 8 Connecting the three wire cable to the generato Pull heat shrink tubing over the solder joint and shrink Pull a suitable shrink tube over each wire of the...

Page 18: ...short circuited via the iSTA Breeze charge controller The wind turbine is braked Press the Charge controller OFF button on the iSTA Breeze charge controller Operation is interrupted Press the Charge c...

Page 19: ...Inspect for damage Wind turbine Check the bolts Electrical wiring Inspect the cables for damage Table 11Inspection and maintenance schedule WARNING Danger due to damaged parts Shut down the wind turbi...

Page 20: ...e tower vertically Tower bends in the wind Design a more robust tower Tower foundation has too much clearance Reduce the clearance to a minimum Wind turbine system produces too little power Wind turbi...

Page 21: ...roughly identical in identical wind conditions 5 What is the battery voltage How old is the battery or batteries 6 Which loads are connected to the battery 7 Are solar panels also connected to the ch...

Page 22: ...the tower On the ground Detach the rotor blades from the generator Detach the generator from the tower and disconnect the electrical wiring Where necessary dispose of the individual components in cons...

Page 23: ...EarthSafe Fig 9 Declaration of conformity Translation of the original instructions iSTA wind turbine system 24 07 2018 I00 23 of 28 13 Declaration of Conformity...

Page 24: ...ions iSTA wind turbine system 24 07 2018 I00 Adapter stud 8 Battery 7 10 11 20 21 Cable cross section 16 20 Charge controller 7 10 11 16 18 20 21 Foundation 14 20 Load 10 14 21 Main components Place o...

Page 25: ...EarthSafe 15 Notes 24 07 2018 I00 Translation of the original instructions iSTA wind turbine system 25 of 28...

Page 26: ...EarthSafe 16 Performance Charts 26 of 28 24 07 2018 I00 Translation of the original instructions iSTA wind turbine system...

Page 27: ...EarthSafe 24 07 2018 I00 Translation of the original instructions iSTA wind turbine system 27 of 28 17 Certificates...

Page 28: ...Serkan r t Riemenstr 31 DE 74906 Bad Rappenau 0049 07264 8899740 www istabreeze com ISTA Breeze No part of this document may be copied or reproduced Translation of the original instructions iSTA wind...

Reviews:

Related manuals for i-300