Connecting procedure
Do not use a Grounding wire between the BlueBox and the embedded target since it
would counteract the primary functionality of the Galvanic Isolation Adapter!
1. Make sure your hardware is powered
OFF
.
·
Embedded Target
·
BlueBox
·
Galvanic Isolation Adapter
2. Connect a Debug Adapter to the BlueBox. Refer to the
on connecting the Debug Adapter.
3. Connect the Debug Adapter to the Galvanic Isolation Adapter.
4. Connect 1:1 Ribbon cable which is delivered along this package to the Galvanic Isolation
Adapter.
5. Connect 1:1 Ribbon cable to the embedded target.
6. Connect BlueBox, Galvanic Isolation Adapter and Target to the power supply.
Use only original iSYSTEM USB-C Power supply for powering and connecting with the
Galvanic Isolation Adapter, otherwise the primary functionality of the Galvanic Isolation
Adapter would be counteracted.
7. Power
ON
the hardware in the following order:
·
BlueBox
·
Galvanic Isolation Adapter
·
Target
If LEDs on the Galvanic Isolation Adapter are
OFF
, immediately turn everything
OFF
!