IMB222
Rev.4.05 May 2022
54
By clicking OK, the main communication page is displayed and an automatic device search
is started.
By clicking on the "Set default values" button on the device the factory values are restored:
-
Modbus address: 1;
-
Baud rate: 9600bps;
-
Parity: none;
-
Stop bit nr.: 1;
-
Modbus delay:0mS
-
Peaks reset
-
Watch dog: 0.5sec
-
User Span: according to model
-
Error correction:0
-
2Wire compensation (only for RTD model):0
14.1.6 Configuration file
Click on menu "File-> save as" to save the configuration. The default path for the file is:
"Documents \ Italcoppie \ EvoPlatform \ ConfigEvoPlatform \ EvominiSER". The default name
for the file corresponds to the device serial number with .ini extension. However, it is possible
to select a desired path and file name. The saved file can be opened with a text editor.
In Figure 24 is reported an example of a .ini file saved for a device with serial number 100.
If more devices are connected to the network, more files can be saved with different names.
Figure 24: EvominiSER configuration file