- 41
-
ENGLISH
fi g. G
fi g. D
fi g. E
5
2
fi g. F
B
A
B
A
MAINTENANCE
SEAS ONAL MAINTE NANCE
(implemented by the
DEALER )
Consists in:
• Clean the boiler-stove internally and externally
• Carefully clean the heat exchange tubes
• Carefully clean and remove dirt from the combustion chamber
and the relative compartment
• Clean fans, verify mechanical and clamp loosening
• Clean smoke channel (replace seals on smoke exhaust pipe)
• Clean smoke duct
• Check the expansion tank
• Verifi cation and cleaning of the circulator installed on the
optional kit
• Clean smoke extraction fan compartment.
• Clean smoke fl ow sensor.
• Clean smoke check thermocouple.
• Empty the pellet hopper and clean the base with the vacuum
cleaner.
• Clean, inspect and scrape any residue from the ignition resistan-
ce compartment and if necessary, replace it
• Clean/check the Synoptic Panel
• Visually inspect the electrical wires, connections and power
cable
• Check play of the screw-gear motor group
• Clean the pellet hopper and check loosening of the feed screw -
gear motor assembly
• Replace the door seal
• Functionality test: load the feed screw, ignite, let it run for 10
minutes and shutdown
If the boiler-stove is used very frequently, it is advisable to
clean the smoke channel and the fume duct every 3 months.
Cleaning the smoke channel
• When the boiler-stove is off and cold, move the cleaning handle
vigorously (see previous page)
• Remove the ash tray (2 - fi g. D), lift the inspection metal plate
and vacuum inside (5 - fi g. E).
The quantity of residue which forms depends on the type of fuel
and the type of system.
If cleaning is not carried out, the boiler-stove may not function
properly.
N.B.: after having completed the operation, make sure that
the two inspection hatches of the smoke channel are correctly
repositioned.
ATTENTION !!!
After implementing a normal cleaning procedure, INCORRE
CT coupling of the upper (A) (fi gura F) and lower (B) (fi gura
F) combustion chambers can compromise the boiler-stove’s
performance.
Before igniting the boiler-stove, make sure the combustion
chambers are correctly paired as indicated in (fi g. G) without
ash or unburnt material present on the support perimeter.
Summary of Contents for NELLY PIU
Page 156: ...156...
Page 159: ...159 cod 941208 03 15 A w w w e d i l k a m i n c o m...