Green Heating Technology
13
6 .
use the buttons
and
for modifying the starting time of the first time slot of DHW heat-
ing activation (10 minutes steps), and then press
;
Note: timings are stored exclusively by pressing the button
. Besides, this will position the
programming on the following event.
7 .
the symbol
as well as another time appears, which means that the first
deactivation is set
on that time;
8 .
press
(the time blinks); use the buttons
and
for modifying the ending time of the
first time slot
of Acqua Step activation (10 minutes steps), and then press
;
9 .
the display now shows a little number
"2"
on the upper-left part, the symbol
and a time,
meaning that you are programming the second time slot
of the DHW heating function, of the same
day. Proceed in the same way as you just did for the first time slot;
10 .
after the last press of the button
the day
2
is selected and you can set
it as described for the day
1
; otherwise you can
copy
the day
1
schedule on
the day
2
as follows:
•
return to day
1
, already programmed, using the button
. Then, press
the button
for 5 seconds: the symbol of the day
2
will be flashing;
•
press
to confirm the copy of the day
1
on the day
2
and skip to this lat-
ter;
• similarly, to copy the program to the further day 3 after (and so on), it's sufficient to press the
button
for 5 seconds, and press
to confirm the copy.
11 .
press the button
for at least 5 seconds to exit and return in winter or summer mode as at the
beginning.
INFO menu
It is possible to get a few information displayed on the screen as far as regards the boiler functioning
which can be showed on some different screen pages. Usually they are useful for the Technician only.
Anyway, even the user can look at them without affecting the good working of the boiler.
f
With the boiler in winter or summer mode (no OFF mode), press the button
for at least 5 sec-
onds;
f
the display will show the
page
(information about the
current work
in progress):
•
…
:
boiler cycle in progress (technician reserved information)
•
heating mode ON,
DHW ON: shown symbol = available function; if flashing, the mode is
in progress;
activated zone(s),
solar system
•
= Burner ON
•
indicator number
1
: CH system flow temperature in
°C
•
indicator number
2
: DHW temperature in °C (meas
-
ured by the central sensor of the solar storage)
•
indicator number
3
: burner power in % from 0 to 99
(0 = minimum)
•
indicator number
4
: CH system return temperature
in °C
TIME SLOT
or DAY
forward -
backward
TIME
increase -
decrease
00148 A 01
1