ATTENTION: the anti-frost protections cannot intervene in the absence of electricity. If you an
-
ticipate this possibility, we recommend you add a good brand of anti-freeze to the heating sys
-
tem, following the producer’s instructions.
We recommend to ask directly the installer/technician about the type of antifreeze product
put in the heating system during installation.
When the power comes back on, the boiler will check the temperature measured by the two
probes and, if it suspects freezing verified by a particular automatic control cycle, alarm 39 will
be triggered. For more details, see the relative description in the paragraph "Alarms - boiler
block" on page 44.
We recommend that you completely empty the hot and cold sanitary water system. The anti-
frost function does not protect the sanitary circuit outside the boiler.
“Ambient Anti‑Frost” Function
Note: if you want to use the “Ambient Anti-Frost” function that is often available in common room
thermostats or chronothermostats, it is necessary to leave the boiler on Winter
+
mode
and NOT o
n OFF mode.
The “Ambient Anti-Frost” function does not protect the sanitary circuit outside the boiler and,
especially, in areas where the heating system doesn’t reach. For this reason, we recommend
that you empty the cold and hot sanitary system, if they were at risk of freezing.
Installation
Law and regulation prescriptions for the installer
Note for the translator/writer:
Place in this paragraph all the recommendations relevant to the compli
-
ance with laws in the destination nation/country (if any). As an example (from Italian regulation):
Characteristics of the room:
as this boiler has an heat output lower than 35 kW (about 30000 Kcal/h),
it is not required to install the appliance in a dedicated room, provided that the room complies with
the regulation in force and that all installation rules assuring a safe and regular gas boiler operation,
are strictly respected.
Permanent ventilation of the installation room is mandatory and extremely important when
a boiler with air draught from the installation room (B… appliance type) is installed. Ventilation
must be made and sized in compliance with Laws and Rules in force.
Instructing the user:
at the end of the installation, the installer must:
• explain the operation of the boiler and its safety devices to the user;
• give this user this booklet and the documentation within his/her competence, duly filled in where
required.