Signal
Probable causes
Suggested solutions
E50
Electric supply out of
tolerance for 3 times
in last 5 minutes.
Verify, with qualified person, that Electric Supply and its tolerances
are respecting "Technical data" on page 52.
E51
Failure to the solar
collector tempera-
ture probe.
Check the cabling of the solar collector temperature probe (outside
the boiler).
Replacement of the solar collector temperature probe.
E52
Failure to the lower
temperature probe
of the DHW stor-
age.
Check the cabling of the lower temperature probe of the DHW stor-
age.
Replacement of the lower temperature probe of the DHW storage.
E53
Failure to the up-
per temperature
probe of the DHW
storage.
Check the cabling of the upper temperature probe of the DHW stor-
age.
Replacement of the upper temperature probe of the DHW storage.
E54
Failure to the cen-
tral temperature
probe of the DHW
storage.
Check the cabling of the central temperature probe of the DHW
storage.
Replacement of the central temperature probe of the DHW storage.
E62
C o m m u n i cat i o n
error between the
Display Board and
the Main PCB.
Refer to the electric diagram (page 56) and check the integrity of the
wirings between the Display Board and the Main PCB.
Replace the Display Board and the Main PCB.
E70
Error: parameter(s)
70…99 out of range
Check that values of parameters 70…99 are correct. The boiler will
return to normal work as soon as all the values are correct.
Particularly, check these
parameters=values: 70=1; 81=1
for the
boiler's correct work.
E77
"Test Service" func-
tion is turned on.
It indicates that the "Test Service" function (for technicians only)
is ON.
E91
System pressure
transducer failure.
Check the cabling of the system pressure transducer.
Replacement of the system pressure transducer.
E92
Excessive system
pressure.
User:
Try reducing the system pressure (e.g. draining some water
from the purging valve of a radiator or similar) and eventually press
the
button. It could be useful to set the display of the system
pressure, that normally should be about 1 Bar (ved. "Set the display
with 4 digits" on page 11).
If the lockout persists or reappears, call the Service Centre.
Check the efficiency of the expansion vessel.
Check the correct shutting of the filling electrovalve, the efficiency
of the relevant filter and che presence of solid particles in the elec
-
trovalve body.