Green Heating Technology
39
Gas conversion
ATTENTION: the operations described below must be carried out only by qualified personnel.
This boiler is designed and prepared to be supplied with Natural Gas G20 (Methane). It can be
set,
just by means of electronic settings, but
always by a qualified technician, to operate with
Commercial Propane G31, for which it is absolutely necessary to install a pressure reducer
upstream the boiler.
It must never be used with Butane gas G30
(that can be present, pure or mixed with Propane G31,
in the portable gas bottles for cookers)
therefore we recommend to inform, about this, the sup-
plier of the fuel.
1.
the boiler should be electrically powered and set in a mode different than
. Use the but
-
ton
if necessary;
2.
set the parameter
01
(see "PCB parameters settings (technician menu)" on page 31) on the re
-
quired gas kind the boiler is required to work with:
•
0
=
Natural gas (G20),
•
1
=
Propane (G31)
3.
ensure that the inlet gas pressure complies with the required nominal pressure (see "Technical
data" on page 47) and that the gas flow is sufficient to guarantee the appliance correct work
with burner ON;
4.
we suggest to
clean the burner and exchanger
as described in the paragraph "Combustion group
cleaning and check" on page 30 (
except
for the case of first ignition, new burner).
5.
carry out the
AUTOmatic combustion calibration
- see paragraph "Combustion calibration" on
page 37 ;
6.
carry out the
combustion test
- see paragraph "Combustion test" on page 35 ;
7.
apply the label indicating the type of gas (provided with the kit) in the area provided on the “WARN
-
ING” plate inside the boiler; besides, write down the new configuration code of the main board
(see table "Board configuration codes" on page 38)
I
n the case of liquid gas fuel, it is important that
the boiler be exclusively fuelled with commer-
cial Propane G31
and not with Butane G30. For this reason, we recommend that
the supplier
of the fuel be informed
, for example,
by applying a suitable warning on the gas tank
or in its
immediate vicinity,
so that it is visible
to the employee at the time it is being filled.