TECHNICAL DATA
(cont'd)
U.M.
City Class 25 K
City Class 30 K
City Class 35 K
Gas type
G20
G31
G20
G31
G20
G31
Loss of water pressure switch
off / on pressure
bar
0.4 / 0.9
(±0.2)
0.4 / 0.9
(±0.2)
0.4 / 0.9
(±0.2)
To allow the correct system filling, the pressure of the domestic water should be
higher than the ON value of the pressure switch.
Max working pressure
bar
3
3
3
Max system temperature
°C
90
90
90
Anti-freezing function temperature on / off
°C
5 / 30
5 / 30
5 / 30
HOT WATER
Flow rate at 25°C temp. rise
l/min
14.8
17.0
18.7
Flow rate at 30°C temp. rise
l/min
12.0
13.8
16.0
Min water flow
(for the DHW function activation)
l/min
2.8
2.8
2.8
Min supply pressure
(for the DHW function activation)
bar
0.2
0.2
0.2
Max supply pressure
bar
6
6
6
Temperature selection range (min÷max)
°C
30÷55
30÷55
30÷55
Flue temperature, average (DHW, ∆T 25°C)
°C
54
59
56
Flue temperature, average (DHW, ∆T 30°C)
°C
57
62
59
ELECTRICAL DATA
Voltage / frequency
(nominal voltage)
V / Hz
220÷240 / 50
(230V)
220÷240 / 50
(230V)
220÷240 / 50
(230V)
Power consumption
W
135
142
150
Level of protection
IP X5D
IP X5D
IP X5D
DIMENSIONS
Width - Height - Depth
mm
see "Dimensions and connections" on page 13
Weight: net / gross
kg
28.4 / 30.8
30.2 / 32.6
34.2 / 36.6
CONNECTIONS
Hydraulic and gas connections
see "Dimensions and connections" on page 13
Flue: types, lengths and diameters
see "Flue systems" on page 21
Fan head loss
Pa
20 ÷ 130
10 ÷ 130
15 ÷ 130
GAS SUPPLY PRESSURE
Nominal pressure
mbar
20
37
20
37
20
37
Inlet pressure (min÷max)
mbar
17 ÷ 25
35÷40
17 ÷ 25
35÷40
17 ÷ 25
35÷40
GAS CONSUMPTION
Qmax
m³/h
2.64
3.17
3.51
kg/h
1.94
2.33
2.57
Qmin
m³/h
0.26
0.32
0.37
kg/h
0.19
0.23
0.27