Green Heating Technology
29
SERVICE
M
anual
City Class F-FR
Technical data
F
U.M.
City Class 20 F
City Class 25 F
City Class 30 F
City Class 35 F
Gas type
G20
G30/G31
G20
G30/G31
G20
G30/G31
G20
G30/G31
Electrical data
Voltage / frequency
(nominal voltage)
220÷240 / 50
(230V)
220÷240 / 50
(230V)
220÷240 / 50
(230V)
220÷240 / 50
(230V)
Power consumption
103
103
132
145
Level of protection
IP X5D
IP X5D
IP X5D
IP X5D
Dimensions
Width - Height - Depth
V / Hz
see "Dimensions and connections"
Weight: net / gross
W
30.4 / 32.8
30.6 / 33.0
31.6 / 34.0
35.8 / 38.2
Connections
Hydraulic and gas
connections
mm
see "Dimensions and connections"
Flue: types, lengths and
diameters
kg
see "Flue systems"
Gas supply pressure
Nominal pressure
mbar
20
37
20
37
20
37
20
37
Inlet pressure (min÷max)
mbar
17 ÷ 25
35÷40
17 ÷ 25
35÷40
17 ÷ 25
35÷40
17 ÷ 25
35÷40
Injectors number
9
11
13
15
Injectors diameter
mm/100
130
78
130
78
130
77
130
78
Gas pressure to injectors at
Qn (MAX)
mbar
12.4
27.8 / 35.7
13.0
27.5 / 35.6
12.8
27.7 / 35.8
12.6
27.4 / 35.4
Gas pressure to injectors at
Qr (MIN)
mbar
2.4
6.5 / 6.5
1.9
4.9 / 4.9
1.9
6.5 / 6.5
1.7
6.5 / 3.9
Gas consumption
at Qn
m³/h
2.22
2.72
3.17
3.65
kg/h
1.61 / 1.59
2.01 / 1.98
2.28 / 2.25
2.72 / 2.67
at Qr
m³/h
1.00
1.06
1.27
1.44
kg/h
0.79 / 0.78
0.80 / 0.79
1.02 / 1.01
1.07 / 1.05
Note:
data have been measured with minimum length coaxial flue.