Green Heating Technology
15
0
1
2
3
4
5
6
7
0
200 400
1000 1200
600 800
1400
0
1
2
3
4
5
6
7
0
200 400
1000 1200
600 800
1400
00381
B 00
pr
essur
e (m H
2
O)
pr
essur
e (m H
2
O)
water flow (l/h)
water flow (l/h)
speed 3 - 2 of the pump
City Class 30 FR
The graph is referred
to the capacity available
to the system.
DHW s
torage c
oil
CH s
ys
tem
0
1
2
3
4
5
6
7
0
200 400
1000 1200
600 800
1400
0
1
2
3
4
5
6
7
0
200 400
1000 1200
600 800
1400
00381
C 00
pr
essur
e (m H
2
O)
pr
essur
e (m H
2
O)
water flow (l/h)
water flow (l/h)
speed 3 - 2 of the pump
City Class 35 FR
The graph is referred
to the capacity available
to the system.
DHW s
torage c
oil
CH s
ys
tem
Warnings for the installation of optional kits or special systems
Floor heating system
The safety thermostat(s) that protects the floor against overheating (that could damage the
cladding, the structure or the system itself) must be installed on the flow starting end of the
serpentine embedded in the floor itself. It should not installed on the system flow pipe in prox-
imity of the boiler, otherwise frequent and unjustified boiler locks, caused by its triggering, are
possible�
Specifications for intake air
Air must be withdrawn from places free of pollutant (like fluorine, chlorine, sulfur, ammonia, alkaline or
similar agents). In the event of installation of the boiler in atmospheres with not negligible presence of
aggressive chemical substances (e.g. hairdressing salons, laundries) we recommend to foresee the air
intake from outdoor, choosing the type C installation.