4
U
T
E
N
T
E
US
E
R
Setting, use and operating and cut-out codes
Note:
the equipment is pre-set to pilot a domestic hot water production system (besides the heating system). It is possible that some commands or displays related to domestic water
production are present, even if the relevant system is not physically connected.
Command keys
Note:
descriptions relate to standard function. In particular cases, e.g. programming, menu activation or in presence of original Remote Control kit (optional), keys may be deactivated
or have different functions from the ones described.
Stand-by / operating mode
At each pressure, boiler switches cyclically from OFF mode to Summer and Winter operating modes. The present mode is indicated
by the writing
OFF
, or through the simultaneous presence of the symbols
and
(Winter mode) or of the symbol
but
not of the symbol
(Summer mode)
or
(Only Heating mode).
Only if combined with
domestic water boiler
heating adjustment
They adjust heating system temperature. If External Probe Kit is installed, see also
"External Probe Kit" on page 23
.
hot water setting:
They adjust water temperature in domestic water storage. As for hot water temperature, see also "Hot water commands" on page 6. Only if combined with
domestic water boiler
It shows on the display additional information related to boiler operation. (For details, see "Menu INFO" on page 8).
Press it in order to restore boiler operation after a shut-down.
See "Alarms - boiler shut-down" on page 33 for details on possible shut-downs.
It manually sets activation and deactivation of the boiler quick preparation function.
Only if combined with
domestic water boiler
It activates automatic time programming of the boiler preparation function. It is used also in its programming and in the clock setting. Only if combined with
domestic water boiler
The first ignition must be carried out by qualified personnel (e.g. the installer or an ITALTHERM
authorised Servicing Centre).
SPecIal recoMMenDatIonS
If you smell gas:
- close gas cock,
- open the window,
- do not use any electrical switches,
- extinguish any flames,
- contact the Service Center or installer immediately.
RECOMMENDATIONS FOR USE
- Due to the dangers implied, it is strictly forbidden to use exhausts, fire places, etc. with the
thermal module, unless the latter is of the sealed-chamber type or special safety measures
are taken during the installation of the thermal module (also in case of future changes or
extensions).
-
Check system pressure at regular intervals on the hydrometer, and make sure that the reading
at cold system is always within the limits specified by the manufacturer. In case of frequent
pressure drops, request the assistance of qualified skilled personnel to eliminate any water
leakage from the boiler.
- Every time the gas cock is reopened, wait for a few minutes before starting the thermal
module again.
- In case of long inactivity periods, close the gas cock and disconnect the main power supply.
- During and for some time after thermal module operation, avoid touching hot parts such as
fume box, flue duct, etc. Any contact with hot parts can lead to serious burns.
- Do not expose the suspended thermal module to the direct steam coming from the hobs.
- Do not let the thermal module get wet from splashing liquids or water.
- Do not place anything on top of the thermal module.
- Do not allow children or inexperienced persons to use the thermal module.
- In case of temporary disuse the following steps should be carried out:
a) empty the water system, if there is no antifreeze;
b) switch off electricity, water and fuel supplies.
- If the thermal module is no longer to be used at all, qualified personnel should carry out the
necessary operations, checking that the electricity, water and fuel supplies are switched off.
- Before carrying out any operation that involves disassembling the boiler or opening covers
or inspection doors, switch off the power supply and turn off gas supply cocks.
Summary of Contents for Time Power 115 K
Page 42: ...42 Notes...
Page 43: ...43 Notes...