NOMENCLATURE AND FUCTIONS

7

8.  INPUT
     MIC 

Balanced inputs(MIC1\MIC2\MIC3\MIC4) 

 

9.  INPUT

     EMC Input Fire alarm signal input(EMC1\EMC2) 

10.INPUT

Auxiliary input jack, Non-equilibrium of connecting  

     peripherals signal(AUX1\AUX2\AUX3)

    

     

11.OUT 

     Line output, Non-equilibrium type, the output of 
     all input signals. 

12.~230V/50Hz AC POWER INPUT
13.LINE INPUT 

     EMC(1~2) Input Fire alarm signal input

14.LINE INPUT

 

    

 

MIC

 

Balanced inputs(MIC(1~5))

     

    

8

13

4.2   REAR  PANEL

T-6201

MIC 4

MIC 3

MIC 2

MIC 1

EMC 1

EMC 2

OUTPUT

AUX 3

AUX 1

INPUT

INPUT

~230V  50Hz
  T1AL250V

MIC 4

MIC 5

MIC 3

MIC 2

MIC 1

EMC 1

EMC 2

LINE  INPUT

RISK OF ELECTRIC SHOCK

DO NOT OPEN

RISQUE DE CHOC ELECTRICUS 
-NE PAS QUVRIR

AVIS:

 PUBLIC ADDRESS SYSTEM

SERIAL  NO

:

9

10

11

12

14

AUX 2

Summary of Contents for T-6201

Page 1: ...ATION MANUAL AUDIO AUDIO PUBLIC ADDRESS SYSTEM T 6201 POWER T 6201 MIXER PRE AMPLIFIER ON OFF MIC 5 TREBLE AUX 1 AUX 2 AUX 3 MIC 1 MIC 2 MIC 3 MIC 4 BASS 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 0 5 4 3 2 1 1 2 3 4 5 0 5 4 3 2 1 1 2 3 4 5 MIC ...

Page 2: ... 1 SAFETY PRECAUTIONS 3 2 GENERAL DESCRIPTION 5 3 FEATURES 5 4 NOMENCLATURE AND FUNCTIONS 4 1 Front Panel 6 4 2 Rear Panel 7 5 MACHINE OPERATING 8 6 APPLICATIONS 9 7 BLOCK DIAGRAM 10 8 SPECIFICATIONS 11 9 DIMENSIONAL DIAGRAM 12 ...

Page 3: ...n fire or electric shock Be sure to replace the unit s terminal cover after connection completion Because high voltage is applied to the speaker terminals never touch these terminals to avoid electric shock Be sure to ground to the safety ground earth terminal to avoid electric shock Never ground to a gas pipe as a catastrophic disaster may result Avoid installing or mounting the unit in unstable ...

Page 4: ...ooty smoke or steam as doing otherwise may result in fire or electric shock When the Unit is in Use Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and or property damage In addition the object itself may fall off and cause injury and or damage Make sure that the volume control is set to minimum position before power is switched on L...

Page 5: ...uts three AUX level input and two EMC priority level inputs 2 GENERAL DESCRIPTION 1 Five MIC inputs 2 Three AUX inputs 3 Two EMC priority input 4 Two stereo aux input and two line input 5 EMC 1 input with priority over all other inputs except MIC 5 6 AUX MIC Tuner Bass Treble volume control T 6201 ...

Page 6: ...ticlockwise to reduce it 5 AUX1 AUX2 AUX3 AUX volume control AUX 1 AUX 2 AUX3 6 MIC 1 5 MIC volume control MIC 1 5 7 MIC MIC1 input 6 3 Microphone jack input 6 1 4 1 FRONT PANEL T 6201 POWER T 6201 MIXER PRE AMPLIFIER ON OFF MIC 5 TREBLE AUX 1 AUX 2 AUX 3 MIC 1 MIC 2 MIC 3 MIC 4 BASS 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 ...

Page 7: ... type the output of all input signals 12 230V 50Hz AC POWER INPUT 13 LINE INPUT EMC 1 2 Input Fire alarm signal input 14 LINE INPUT MIC Balanced inputs MIC 1 5 8 13 4 2 REAR PANEL T 6201 MIC 4 MIC 3 MIC 2 MIC 1 EMC 1 EMC 2 OUTPUT AUX 3 AUX 1 INPUT INPUT 230V 50Hz T1AL250V MIC 4 MIC 5 MIC 3 MIC 2 MIC 1 EMC 1 EMC 2 LINE INPUT RISK OF ELECTRIC SHOCK DO NOT OPEN RISQUE DE CHOC ELECTRICUS NE PAS QUVRIR...

Page 8: ...nd AUX input1 2 3 automatically muted by EMCinput 1 2 EMC 1 or 2 input overrides the MIC1 2 3 4 and AUX 1 2 3 signals The MIC input 1 2 3 4 AUX input 1 2 3 and EMC 1 2 are automaticallymuted by MIC input 1 MIC 5 input overrides the other input signals 8 T 6201 ...

Page 9: ...2 HOT 3 COLD 1 2 3 1 2 3 OUTPUTS INPUTS 230V 50Hz T5AL 250V POWER AMPLIFIER AUDIO SOURCES 230V 50Hz T1AL250V AUDIO OUT R L COM ADRESS TAG MIC 4 MIC 3 MIC 2 MIC 1 EMC 1 EMC 2 OUTPUT AUX 3 AUX 2 AUX 1 INPUT INPUT 230V 50Hz T1AL250V MIC 4 MIC 5 MIC 3 MIC 2 MIC 1 EMC 1 EMC 2 LINE INPUT RISK OF ELECTRIC SHOCK DO NOT OPEN RISQUE DE CHOC ELECTRICUS NE PAS QUVRIR AVIS PUBLIC ADDRESS SYSTEM SERIAL NO 9 T 6...

Page 10: ...7 BLOCK DIAGRAM 10 T 6201 BASS TREBLE VOLUME POWER Z 230V AC 50Hz PT MIC1 EB MIC1 MIC2 EB MIC2 MIC3 EB MIC3 MIC4 EB MIC4 MIC5 EB MIC5 MUTE EB EMC1 EB EMC2 EB AUX1 EB AUX2 EB AUX3 OUT 0 775V ...

Page 11: ... AC fusex1 230V 50Hz 9Kg 8Kg PROTECTION DIMENSION mm NET WEIGHT GROSS WEIGHT POWER REQUIREMENTS 484X353X88 MIC 1 2 3 4 5 600ohms 1 8mv unbalanced AUX 1 2 3 10Kohms 200mv unbalanced TONE Bas 10dB at 100Hz Treble 10dB at 15kHz OUTPUT 600 ohms 1V 0dBV SIGNAL NOISE RATIO MIC input 80dB AUX input 85dB 11 T 6201 ...

Page 12: ... 1 1 2 3 4 5 MIC POWER T 6201 MIXER PRE AMPLIFIER ON OFF MIC 5 TREBLE AUX 1 AUX 2 AUX 3 MIC 1 MIC 2 MIC 3 MIC 4 BASS 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 0 5 4 3 2 1 1 2 3 4 5 0 5 4 3 2 1 1 2 3 4 5 MIC MIC 4 MIC 3 MIC 2 MIC 1 EMC 1 EMC 2 OUTPUT AUX 3 AU...

Page 13: ...AUDIO AUDIO Guangzhou ITC Electronic Technology Limited Http www itc pa com cn PUBLIC ADDRESS SYSTEM 2009 06 Version1 2 ...

Reviews: