6.- START UP AND REGULATION
BASE
: Check that the pump is properly secured to the base.
CHECKING THE HYDRAULIC CIRCUIT
: Check that all valves are
open and the liquid from priming valves are derived correctly
CHECKING OF PUMP
: Visually/hearing check the proper operation of
the pump.
OVER-PRESSURE PROTECTION
: Adjust the safety valve to the
correct pressure to protect the installation without exceeding the pump
nominal pressure.
ELECTRIC PROTECTION
: Ajust the electric protection to the pump
nominal current.
Replace crystal suction hose with a polyethilene discharge hose. Use
PTFE hose for the suction and discharge.
Previously, take away from inside the pump all water present (if water
is mixed with sulphuric acid, an overtemperature is caused, damaging
the pump.
SULPHURIC ACID DOSIFICATION