14
LEVEL ALARM (FAO)
Pump stops, displays FAO, and the alarm LED is on when detecting no product for
five seconds. A level sensor is required.
POWER ON THE PUMP
PRIMING
Select MANUAL function and select the frequency to prime the pump.
F to select MANUAL
+/- to change the injection/min ( a 75% of the maximum frequency is
recommended)
The pump starts with METER, pulse per minute is displayed.
Use mA / pulse, to display input signal / injections per minute.
PROGRAMMING
SET POINT 1
Sets the input signal value for the minimum flow, and the frecuency of the
injections.
F to select SET1/STOP, show the frecuency of the injections set.
+/- to change the frecuency of the injections (puls/min), for minimum flow (000 for
stop)
mA/pulse to select mA.
+/- to change the value of the input signal (mA) for the minimum flow.
Confirm with ENT.
F to select SET POINT 2.