28
PROPORTIONAL MODE
Proportional dosing between the pulses of the water counter, and the pump
injections.
1XN MODE
For each pulse received, the pump injects "N" times. N is set by the user,
frecuency is set in manual mode.
Example:
- Pump set on
1XN
mode.
- N=
20
- When the pump receives a pulse, it starts dosing 20 injections. If the pump
receives another pulse while it is dosing, the pulse is ignored. When the pump
finishes the 20 injections, it can accept another pulse.
1XN (M) MODE
Works as 1xN mode, but frecuency of the pump is adjusted to time between pulses
received. If the pump received a pulse while it is dosing, it is memorized and
adjusts the frecuency again.
Overpulse alarm (AL3)
When the number of pulses remaining to inject is higher than 4xN, AL3 is
activated. The pump continues working, but the pending injections are not done.
Example:
Pump receives a pulse, dose "N" injections at the maximum frecuency (120
injection/minute).
At the second pulse received, the pump adjust the injection frecuency to the time
between first and second pulse. Maximum límit is maximum frecuency.
MENU SELECT
1xN(M)
MENU1xN(M)
10
to set “N” injections
.
Confirm with START /STOP.
1xN(M) n=10
12:00
to set “N” injections
.
Confirm with START/STOP
1x N n= 10
12:00
MENU SELECT
1xN
MENU 1xN
10