ELECTRIC CONNECTION
The electric protection of the motor must be installed and adjusted
following its nominal intensity (overloaded switch disjuntor).
A disconnection dispositive must be installed in case of emergency.
The equipment must be protected to avoid untimely sudden starts.
8
Install a safety valve in a derivation as near as possible
from the pump , in order to protect it and the whole
installation from possible over-pressures. This derivation
Must derive the liquid to a safe place.
To prime the pump, first connect the priming
hose to the priming valve and drive the
other side of the hose to a safety place to
pour the air mixed with product.
Open the priming valve and start the pump
at maximum flow until having only liquid in
the priming outlet.
PRIMING
VALVE
PRIMING
HOSE
Select the most appropiate injection point in
the pipe to inject the product, and place
there a 3/8” part to connect the Injection
valve.
INJECTION
HOSE
3/8”